FireCADCalc

Combined Cycle Efficiency and Power Split

Steam turbine power, total output, efficiency and heat rate of a gas turbine combined cycle from the gas turbine efficiency, HRSG heat recovery and steam cycle efficiency.

Thermal power plantRefinery and petrochemicalChemical and fertiliserBoilerSteam turbine

Inputs

Examples: 100 MW gas turbine at 36 %, 80 % recovery, 33 % steam cycle260 MW F-class at 39 %, 85 %, 36 %, 2.5 % auxiliary25 MW industrial at 32 %, 75 %, 28 %

Gas turbine ratings are usually on the lower heating value (LHV); the fuel heat, efficiencies and heat rate come out on the same basis.

Results

No supplementary firing; the gas turbine's own heat losses (casing, lube oil, generator) are counted as exhaust heat, which slightly overstates the steam power.

Fuel heat input78.125MW
Heat in the gas turbine exhaust53.125MW
Heat recovered in the HRSG39.844MW
Steam turbine power11.156MW
Gross combined cycle output36.156MW
Net output35.072MW
Gross combined cycle efficiency46.280%
Net efficiency44.892%
Net heat rate8,019.3kJ/kWh

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 100 MW gas turbine at 36 %, 80 % recovery, 33 % steam cycle. The inputs, in the units selected above:

InputValue
Gas turbine power100.00 MW
Gas turbine efficiency (on fuel heat)36.000 %
Share of the exhaust heat the HRSG recovers80.000 %
Steam cycle efficiency (power ÷ heat absorbed in the HRSG)33.000 %
Auxiliary power, share of gross output2.0000 %

Applying the formula below gives:

ResultValue
Fuel heat input277.78 MW
Heat in the gas turbine exhaust177.78 MW
Heat recovered in the HRSG142.22 MW
Steam turbine power46.933 MW
Gross combined cycle output146.93 MW
Net output143.99 MW
Gross combined cycle efficiency52.896 %
Net efficiency51.838 %
Net heat rate6,944.7 kJ/kWh

Open this example in the calculator and change any input.

Formula

\(Q_F = \frac{P_{GT}}{\eta_{GT}}, \quad Q_{ex} = Q_F - P_{GT}, \quad Q_R = \eta_R\, Q_{ex}, \quad P_{ST} = \eta_{ST}\, Q_R\)

\(\eta_{CC} = \eta_{GT} + (1 - \eta_{GT})\, \eta_R\, \eta_{ST}\)

\(P_n = (P_{GT} + P_{ST})(1 - a), \quad \eta_n = P_n / Q_F, \quad HR_n = Q_F / P_n\)

Variables

Symbol Meaning SI unit
\(P_{GT}\) Gas turbine power W
\(\eta_{GT}\) Gas turbine efficiency (on fuel heat) -
\(\eta_R\) Share of the exhaust heat the HRSG recovers -
\(\eta_{ST}\) Steam cycle efficiency (power ÷ heat absorbed in the HRSG) -
\(a\) Auxiliary power, share of gross output -
\(Q_F\) Fuel heat input W
\(Q_{ex}\) Heat in the gas turbine exhaust W
\(Q_R\) Heat recovered in the HRSG W
\(P_{ST}\) Steam turbine power W
\(P_g\) Gross combined cycle output W
\(P_n\) Net output W
\(\eta_{CC}\) Gross combined cycle efficiency -
\(\eta_n\) Net efficiency -
\(HR_n\) Net heat rate J/J

Method and standards

An energy balance of the topping and bottoming cycles: the gas turbine's fuel heat less its power is the exhaust heat; the HRSG recovers a share of it; the steam cycle converts that share at its own efficiency.

Where it is used

  • First estimate of a combined cycle or cogeneration conversion.
  • Comparing gas turbine choices for the same steam cycle.
  • Explaining the gain from adding a steam turbine to an open-cycle plant.

Common mistakes

  • Using the steam cycle efficiency on fuel heat instead of heat absorbed in the HRSG.
  • Using lower and higher heating values together.
  • Forgetting the gas turbine output falls with HRSG back pressure.

Assumptions and limits

  • Steady full load; no supplementary firing.
  • Gas turbine losses other than exhaust are counted as exhaust heat.
  • Heating value basis follows the gas turbine efficiency entered, usually LHV; efficiencies and heat rate are on that basis.

References

  • Combined cycle energy balance (Kehlhofer, Hannemann, Stirnimann and Rukes, Combined-Cycle Gas & Steam Turbine Power Plants, 3rd ed., PennWell, 2009)

Questions and answers

What efficiency does a 36 % gas turbine reach in combined cycle?

With 80 % of its exhaust heat recovered and a 33 % steam cycle, 52.9 % gross: the steam turbine adds about 47 MW to a 100 MW gas turbine.

Why is combined cycle so efficient?

The gas turbine rejects its heat at 500–600 °C; the steam cycle uses that heat instead of fuel, so η = η_GT + (1 − η_GT) η_R η_ST.

Is supplementary firing included?

No. Duct firing adds fuel at a lower marginal efficiency; use the HRSG supplementary firing calculator for that.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.