Worked example
Example: 300 MW at 1.6 m/s (300 K), 20 % excess. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Heat input (HHV) | 300.00 MW |
| Superficial velocity referred to 300 K | 1.6000 m/s |
| Excess air coefficient (1.2 = 20 % excess) | 1.2000 - |
| Combustion air volume flow at 300 K (for the check; 0 = none) | 342,000 m³/h |
Applying the formula below gives:
| Result | Value |
|---|---|
| Grate heat release rate | 4.4000 MW/m² |
| Furnace cross-section | 68.182 m² |
| Velocity at 300 K from the gas flow | 1.3933 m/s |
Open this example in the calculator and change any input.
Formula
\(q_A = \frac{3.3U_0}{EAC}\ \mathrm{MW/m^2}, \quad A = \frac{Q}{q_A}, \quad U_{check} = \frac{\dot V_{300}}{A}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(Q\) | Heat input (HHV) | W |
| \(U_0\) | Superficial velocity referred to 300 K | m/s |
| \(EAC\) | Excess air coefficient (1.2 = 20 % excess) | - |
| \(\dot V_{300}\) | Combustion air volume flow at 300 K (for the check) | m³/s |
| \(q_A\) | Grate heat release rate | W/m² |
| \(A\) | Furnace cross-section | m² |
| \(U_{check}\) | Velocity at 300 K from the gas flow | m/s |
Method and standards
Basu's Eq. (4.21).
Where it is used
- First sizing of CFB and BFB furnaces.
Common mistakes
- Using actual velocity at bed temperature for U₀.
- Ignoring excess air.
Assumptions and limits
- Average fossil fuels: about 3.3 MW per m² for each m/s of air at 300 K. Biomass and wet fuels differ.
- Eq. (4.21) is in terms of the air velocity, so the check uses the combustion air flow at 300 K, not the flue gas flow.
- The check velocity is shown only when a gas flow is entered; a warning appears when it differs from U₀ by more than 10 %.
References
- Basu
- Circulating Fluidized Bed Boilers: Design
- Operation and Maintenance (Springer, 2015)
- ch. 4
- Eq. (4.21) (Waters 1975)
Questions and answers
Why is heat release tied to velocity?
Air per MJ of fuel is nearly constant, so the furnace can burn only as much fuel as the air passing through it.
Why referred to 300 K?
It fixes the air mass flow independent of furnace temperature.
What is typical?
CFB boilers release about 3–5 MW/m² of grate; bubbling beds about 1–2.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.