Worked example
Example: 46 bar drum. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Steam flow | 60.000 t/h |
| Drum pressure (absolute) | 46.000 bar |
| Steam-space free area | 1.6000 m² |
| Souders–Brown coefficient | 0.060000 m/s |
Applying the formula below gives:
| Result | Value |
|---|---|
| Water density | 785.52 kg/m³ |
| Steam density | 23.224 kg/m³ |
| Allowable steam velocity | 0.34376 m/s |
| Actual steam velocity | 0.44854 m/s |
| Loading | 130.48 % |
Open this example in the calculator and change any input.
Formula
\(v_{allow} = K\sqrt{\frac{\rho_l - \rho_v}{\rho_v}}, \quad v = \frac{\dot m_s}{\rho_v A}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\dot m_s\) | Steam flow | kg/s |
| \(p_d\) | Drum pressure (absolute) | Pa |
| \(A\) | Steam-space free area | m² |
| \(K\) | Souders–Brown coefficient | m/s |
| \(\rho_l\) | Water density | kg/m³ |
| \(\rho_v\) | Steam density | kg/m³ |
| \(v_{allow}\) | Allowable steam velocity | m/s |
| \(v\) | Actual steam velocity | m/s |
| \(v/v_{allow}\) | Loading | - |
Method and standards
Souders–Brown: the allowable upward steam velocity is K times the square root of the density difference over the steam density (IAPWS-IF97 saturated densities); the actual velocity is the steam volume flow over the free area. The loading is their ratio.
Where it is used
- Drum sizing.
- Carry-over investigations.
Common mistakes
- Gross area used instead of free area.
Assumptions and limits
- Saturated conditions.
- The free area is the plan area of the water surface the steam rises through (for a horizontal drum, length times the surface width at the normal water level).
- The coefficient K carries the result linearly; the default 0.06 m/s is a FireCAD starting value for a plain steam space, not a sourced figure. Use the drum or separator maker's value.
References
- Souders and Brown (1934) v = K √((ρ_l − ρ_v)/ρ_v); saturated densities from IAPWS-IF97
Questions and answers
Why does loading rise at low pressure?
Steam density falls, so the same mass flow needs a higher velocity.
Primary and secondary separators?
They allow far higher loadings than a plain steam space.
Sugar ingress?
Foaming from contaminated condensate reduces the allowable loading sharply.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.