FireCADCalc

Creep Life Fraction by Robinson's Rule

Consumed and remaining creep life of a tube or header from hours and rupture life at up to four conditions (Robinson's life-fraction rule).

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationDistillery and ethanolBoiler

Inputs

Examples: Two conditionsOverheating episode

From the material's stress-rupture or Larson–Miller data at that temperature and stress.
From the material's stress-rupture or Larson–Miller data at that temperature and stress.
From the material's stress-rupture or Larson–Miller data at that temperature and stress.
From the material's stress-rupture or Larson–Miller data at that temperature and stress.

Results

Robinson's rule is an engineering estimate; scatter in rupture data is large, so apply a design margin.

Life fraction used Σ t/t_r42.500%
Life fraction remaining57.500%
Remaining hours at condition 1172,500h

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Two conditions. The inputs, in the units selected above:

InputValue
Hours at condition 160,000 h
Rupture life at condition 1400,000 h
Hours at condition 220,000 h
Rupture life at condition 2120,000 h
Hours at condition 30 h
Rupture life at condition 31,000,000 h
Hours at condition 40 h
Rupture life at condition 41,000,000 h

Applying the formula below gives:

ResultValue
Life fraction used Σ t/t_r31.667 %
Life fraction remaining68.333 %
Remaining hours at condition 1273,333 h

Open this example in the calculator and change any input.

Formula

\(D = \sum_i \frac{t_i}{t_{r,i}}, \quad t_{rem} = \max(0,\ 1 - D)\,t_{r,1}\)

Variables

Symbol Meaning SI unit
\(t_1\) Hours at condition 1 s
\(t_{r,1}\) Rupture life at condition 1 s
\(t_2\) Hours at condition 2 s
\(t_{r,2}\) Rupture life at condition 2 s
\(t_3\) Hours at condition 3 s
\(t_{r,3}\) Rupture life at condition 3 s
\(t_4\) Hours at condition 4 s
\(t_{r,4}\) Rupture life at condition 4 s
\(D\) Life fraction used Σ t/t_r -
\(1 − D\) Life fraction remaining -
\(t_{rem}\) Remaining hours at condition 1 s

Method and standards

Robinson's linear life-fraction rule (E. L. Robinson, Trans. ASME 74, 1952): creep damage is the sum of the time at each condition over the rupture life at that condition, and failure is predicted when the sum reaches 1. The remaining hours are at condition 1 and are shown as zero once the sum reaches 1; the remaining fraction is then negative.

Where it is used

  • Remaining life assessment.
  • Overheating incident reviews.

Common mistakes

  • Rupture life at design rather than actual temperature.

Assumptions and limits

  • Linear damage summation.
  • Remaining hours assume future operation at condition 1; if the tube will run at another condition, put that condition first.

References

  • Robinson's linear life-fraction rule D = Σ t_i/t_r
  • i; rupture lives from the user's material data (e.g. via the Larson–Miller parameter)

Questions and answers

What is Robinson's rule?

Creep damage adds up as the sum of time spent at each condition divided by the rupture time at that condition.

Where do rupture lives come from?

The material's stress-rupture data at the metal temperature and hoop stress; the Larson–Miller calculator converts between them.

Why do a few hot hours matter?

Rupture life falls steeply with temperature: overheating periods dominate the sum.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.