Steam-Side Oxide Growth and Tube Metal Temperature Rise

Oxide thickness after a service time by the parabolic law from a rate constant, and the metal temperature rise the scale causes at a heat flux.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationDistillery and ethanolBoiler

Inputs

Examples: 50 um, 50 000 hFresh tubek_p given as 1e-12 cm2/s (0.36 um2/h)

From oxide measurements on your tubes or published data for the alloy.

Results

A hotter tube oxidises faster: the rate constant rises with temperature, so remaining life can fall quickly.

Oxide thickness then122.47µm
Metal temperature rise now5.0000K
Metal temperature rise then12.247K

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 50 um, 50 000 h. The inputs, in the units selected above:

InputValue
Oxide thickness now50.000 µm
Parabolic rate constant at metal temperature (in the units chosen below)0.25000 -
Units of the rate constantµm²/h
Further service time50,000 h
Heat flux through the tube wall60.000 kW/m²
Oxide thermal conductivity0.60000 W/(m·K)

Applying the formula below gives:

ResultValue
Oxide thickness then122.47 µm
Metal temperature rise now5.0000 K
Metal temperature rise then12.247 K

Open this example in the calculator and change any input.

Formula

\(x = \sqrt{x_0^2 + k_p t}, \quad \Delta T = \frac{q x}{k_{ox}}\)

Variables

Symbol Meaning SI unit
\(x_0\) Oxide thickness now m
\(k_p\) Parabolic rate constant at metal temperature, in the units chosen (µm²/h, mm²/h, cm²/s or m²/s) m²/s
\([k_p]\) Units of the rate constant -
\(t\) Further service time s
\(q\) Heat flux through the tube wall W/m²
\(k_{ox}\) Oxide thermal conductivity W/(m·K)
\(x\) Oxide thickness then m
\(\Delta T_0\) Metal temperature rise now K
\(\Delta T\) Metal temperature rise then K

Method and standards

Parabolic oxidation law, x² = x₀² + k_p t, with the rate constant converted to m²/s from the units chosen; the temperature rise is one-dimensional conduction through the oxide at the heat flux entered.

Where it is used

  • Remaining life assessment.
  • Superheater inspection planning.

Common mistakes

  • Rate constant at the wrong temperature.

Assumptions and limits

  • Constant metal temperature: the rate constant is held fixed although the growing oxide raises the metal temperature and so the rate (the calculation does not iterate). Re-run with a higher k_p as the tube heats up.
  • The default oxide conductivity, 0.6 W/(m·K), is a FireCAD starting value, not a sourced figure; use measured or published data for your oxide.

References

  • Parabolic oxidation law x² = x₀² + k_p t; conduction through the scale ΔT = q x/k (rate constant from user data)

Questions and answers

Why does oxide matter?

It insulates the tube, raising metal temperature and shortening creep life.

Where does k_p come from?

Measured oxide thickness and operating hours on your tubes, or published data for the alloy and temperature.

Exfoliation?

Thick scales spall and can block bends: another reason to track them.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.