Nucleate Boiling Coefficient (Cooper Correlation)

Pool nucleate boiling heat-transfer coefficient and wall superheat for water from the reduced pressure, molar mass and heat flux by Cooper's correlation.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationDistillery and ethanolIAPWS-IF97 (water and steam)Boiler

Inputs

Examples: 70 bar, 150 kW/m210 bar, 50 kW/m2

22.064 MPa (220.64 bar) for water (IAPWS-IF97); enter the fluid's own value for other fluids.

Results

Cooper's form for a surface roughness of about 1 µm. For water keep M = 18.015 kg/kmol and p_c = 22.064 MPa (IAPWS); for other fluids enter their own M and p_c.

Reduced pressure p/p_c0.045323
Boiling coefficient10,692W/(m²·K)
Wall superheat4.6765K

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 70 bar, 150 kW/m2. The inputs, in the units selected above:

InputValue
Pressure (absolute)70.000 bar
Heat flux150.00 kW/m²
Molar mass of the fluid18.015 kg/kmol
Critical pressure of the fluid220.64 bar

Applying the formula below gives:

ResultValue
Reduced pressure p/p_c0.31726
Boiling coefficient48,634 W/(m²·K)
Wall superheat3.0843 K

Open this example in the calculator and change any input.

Formula

\(p_r = \frac{p}{p_c}, \quad h = 55\,p_r^{0.12}(-\log_{10} p_r)^{-0.55} M^{-0.5} q^{0.67}\)

Variables

Symbol Meaning SI unit
\(p\) Pressure (absolute) Pa
\(q\) Heat flux W/m²
\(M\) Molar mass of the fluid kg/kmol
\(R_p\) surface roughness (taken as 1 µm) µm
\(p_c\) Critical pressure of the fluid (water 22.064 MPa) Pa
\(p_r\) Reduced pressure p/p_c -
\(h\) Boiling coefficient W/(m²·K)
\(\Delta T_{sat}\) Wall superheat K

Method and standards

Cooper (1984) pool boiling correlation. Its full form has the exponent of p_r as 0.12 − 0.2 log₁₀ R_p, with R_p the surface roughness in µm; here R_p = 1 µm, so the exponent is 0.12.

Where it is used

  • Evaporator and water-wall tube temperatures.

Common mistakes

  • Heat flux in kW/m² in the formula.

Assumptions and limits

  • Nucleate regime, below CHF. The heat flux is not checked against the critical heat flux: check it with the Zuber CHF calculator.
  • Surface roughness about 1 µm (commercial tubes).
  • Pressure below the fluid's critical pressure; defaults are for water.

References

  • Cooper (1984)
  • h = 55 p_r^0.12 (−log₁₀ p_r)^−0.55 M^−0.5 q^0.67 (W/m²K, q in W/m²); p_c entered (water 22.064 MPa, IAPWS-IF97)

Questions and answers

Why does h rise with pressure?

Bubbles nucleate more readily as the fluid approaches its critical point.

Is this pool or flow boiling?

Pool; flow boiling adds a convective part (Chen-type methods).

Why is the water-side resistance small?

Boiling coefficients are tens of kW/m²K, far above the gas side.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.