Natural Circulation Driving Head (Downcomer vs Riser)

Driving pressure of a natural-circulation loop from the drum pressure, the circuit height and the mean riser quality (homogeneous model, IF97 densities).

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationDistillery and ethanolIAPWS-IF97 (water and steam)Boiler

Inputs

Examples: 70 bar, 25 m32 bar, 18 m

Results

The head must balance the friction and acceleration losses of the loop at the circulation ratio chosen; head falls as drum pressure rises.

Downcomer water density (saturated)816.92kg/m³
Mean riser density (homogeneous)272.17kg/m³
Driving head96.158kPa

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 70 bar, 25 m. The inputs, in the units selected above:

InputValue
Drum pressure (absolute)70.000 bar
Height of the heated riser above the downcomer bottom25.000 m
Mean riser quality5.0000 %

Applying the formula below gives:

ResultValue
Downcomer water density (saturated)739.72 kg/m³
Mean riser density (homogeneous)376.90 kg/m³
Driving head88.953 kPa

Open this example in the calculator and change any input.

Formula

\(\rho_r = \left(\frac{\bar x}{\rho_v} + \frac{1-\bar x}{\rho_l}\right)^{-1}, \quad \Delta p_d = g H (\rho_l - \rho_r)\)

Variables

Symbol Meaning SI unit
\(p_d\) Drum pressure (absolute) Pa
\(H\) Height of the heated riser above the downcomer bottom m
\(\bar x\) Mean riser quality -
\(\rho_l\) Downcomer water density (saturated) kg/m³
\(\rho_r\) Mean riser density (homogeneous) kg/m³
\(\Delta p_d\) Driving head Pa

Method and standards

Hydrostatics of the loop: the driving head is g H times the density difference between the saturated water in the downcomer and the two-phase riser mixture, with the riser density from the homogeneous (no-slip) model at the mean quality and IAPWS-IF97 saturated densities.

Where it is used

  • Circulation design checks.

Common mistakes

  • Exit quality used as mean.

Assumptions and limits

  • Saturated downcomer water.
  • Homogeneous (no-slip) riser density at one mean quality: slip and the averaging of density along the riser both raise the true riser density, so the head is overstated (an upper bound).

References

  • Δp = g H (ρ_l − ρ_r) with homogeneous riser density; IAPWS-IF97 saturated densities

Questions and answers

Why does circulation weaken at high pressure?

Water and steam densities converge, so the density difference shrinks.

Homogeneous or slip?

Slip raises riser density and lowers the head; the homogeneous value is an upper bound.

Mean riser quality?

Roughly half the riser exit quality for uniform heating. Because the mixture density is not linear in quality, the true length-averaged riser density is higher than the density at that mean quality, so the head found this way is an upper bound.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.