Drum Warm-Up: Through-Wall ΔT and Thermal Stress for a Heating Rate

Quasi-steady through-wall temperature difference and surface thermal stress of a thick drum or header wall heated at a constant rate, and the rate for an allowed ΔT.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationDistillery and ethanolBoiler

Inputs

Examples: 90 mm drum at 100 °C/h50 mm header

Results

Plane wall, outer face insulated, quasi-steady heating; drum curvature, the initial transient and stress concentration at nozzles (which usually govern start-up limits) are not included. Code start-up curves (EN 12952-3 and similar) govern design limits; this is an engineering estimate.

Thermal diffusivity9.8619mm²/s
Through-wall temperature difference7.0417K
Surface thermal stress (magnitude; compressive at the inner surface while heating)17.001MPa
Heating rate for the allowed ΔT852.07°C/h

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 90 mm drum at 100 °C/h. The inputs, in the units selected above:

InputValue
Wall thickness90.000 mm
Heating rate of the inner surface100.00 °C/h
Steel thermal conductivity45.000 W/(m·K)
Steel density7,850.0 kg/m³
Steel specific heat0.50000 kJ/(kg·K)
Young's modulus200.00 GPa
Linear expansion coefficient13.000 µm/(m·K)
Poisson's ratio0.30000 -
Allowed through-wall ΔT40.000 K

Applying the formula below gives:

ResultValue
Thermal diffusivity11.465 mm²/s
Through-wall temperature difference9.8125 K
Surface thermal stress (magnitude; compressive at the inner surface while heating)24.298 MPa
Heating rate for the allowed ΔT407.64 °C/h

Open this example in the calculator and change any input.

Formula

\(\alpha = \frac{k}{\rho c_p}, \quad \Delta T = \frac{\dot T s^2}{2\alpha}, \quad \sigma = \frac{E \beta}{1 - \nu}\cdot\frac{2}{3}\Delta T, \quad \dot T_{allow} = \frac{2\alpha\,\Delta T_{allow}}{s^2}\)

Variables

Symbol Meaning SI unit
\(s\) Wall thickness m
\(\dot T\) Heating rate of the inner surface K/s
\(k\) Steel thermal conductivity W/(m·K)
\(\rho\) Steel density kg/m³
\(c_p\) Steel specific heat J/(kg·K)
\(E\) Young's modulus Pa
\(\beta\) Linear expansion coefficient 1/K
\(\nu\) Poisson's ratio -
\(\Delta T_{allow}\) Allowed through-wall ΔT K
\(\alpha\) Thermal diffusivity m²/s
\(\Delta T\) Through-wall temperature difference K
\(\sigma\) Surface thermal stress Pa
\(\dot T_{allow}\) Heating rate for the allowed ΔT K/s

Method and standards

One-dimensional heat conduction in a plane wall heated at a constant rate on the inside with the outside insulated: after the initial transient the temperature profile is a parabola that moves with the ramp (Carslaw and Jaeger). The surface stress follows from the difference between the mean and surface temperatures for a wall restrained against bending (Timoshenko). EN 12952-3 and similar codes set the actual start-up limits from pressure and thermal stress together with fatigue; they are not applied here.

Where it is used

  • Start-up procedures.
  • Cycling studies.

Common mistakes

  • Using outer-surface rates.

Assumptions and limits

  • Plane wall; constant properties. Drum curvature (thick cylinder) and the initial transient are neglected.
  • Stress concentrations at nozzles and tube holes, which usually govern drum start-up limits, are not included.
  • The stress is shown as a magnitude: during heating the inner surface is in compression, during cooling in tension.

References

  • EN 12952-3 (start-up limits, for context; not applied)
  • Quasi-steady heating of a plane wall at a constant rate
  • ΔT = Ṫ s²/(2α) (Carslaw and Jaeger); surface stress E β (T_mean − T_s)/(1 − ν) with T_mean − T_s = 2ΔT/3 (Timoshenko)

Questions and answers

Why does thickness matter so much?

ΔT grows with the square of thickness: thick drums must warm slowly.

Is this the code start-up limit?

No: codes combine pressure and thermal stress with fatigue; use this to understand and estimate.

Why quasi-steady?

After an initial transient the profile through the wall settles into a parabola that moves with the ramp.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.