FireCADCalc

Bagasse and Biomass Boiler Steam-to-Fuel Ratio

Steam per tonne of bagasse, rice husk or other biomass from its dry calorific value, moisture, boiler efficiency and steam conditions (IAPWS-IF97).

Process steam and utilitiesSugar mill and cogenerationPulp and paperFood, dairy and textileIAPWS-IF97 (water and steam)Boiler

Inputs

Examples: Bagasse 50 % moisture, 19.0 MJ/kg dry, 68 %, 45 bar(a) / 400 °C, feed 140 °CBagasse 48 %, 19.0 MJ/kg, 72 %, 67 bar(a) / 485 °C, 170 °CRice husk 10 %, 15.0 MJ/kg, 76 %, 17.5 bar(a) sat, 105 °C

From a lab analysis of your fuel.

Results

Efficiency itself falls as moisture rises; use the efficiency for this moisture (indirect method) rather than a fixed figure.

Steam per kg of fuel4.3588kg/kg
Fuel per kg of steam229.42kg/t
Gross calorific value as fired13,500kJ/kg
Heat added per kg of steam2,353.9kJ/kg

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Bagasse 50 % moisture, 19.0 MJ/kg dry, 68 %, 45 bar(a) / 400 °C, feed 140 °C. The inputs, in the units selected above:

InputValue
Gross calorific value, dry basis19,000 kJ/kg
Moisture as fired50.000 %
Boiler efficiency (on GCV)68.000 %
Steam pressure (absolute)45.000 bar
Steam conditionSuperheated at the temperature below
Steam temperature (superheated only)400.00 °C
Feedwater temperature140.00 °C

Applying the formula below gives:

ResultValue
Steam per kg of fuel2.4716 kg/kg
Fuel per kg of steam404.59 kg/t
Gross calorific value as fired9,500.0 kJ/kg
Heat added per kg of steam2,613.7 kJ/kg

Open this example in the calculator and change any input.

Formula

\(GCV_{ar} = GCV_d\,(1 - M) \qquad SFR = \frac{\eta\,GCV_{ar}}{h_s - h_{fw}} \qquad \frac{1}{SFR}\)

Variables

Symbol Meaning SI unit
\(GCV_d\) gross calorific value, dry J/kg
\(M\) moisture as fired –
\(\eta\) boiler efficiency on GCV –
\(p\) steam pressure Pa
\(\text{state}\) saturated or superheated –
\(T_s\) steam temperature K
\(T_{fw}\) feedwater temperature K
\(SFR\) steam per kg of fuel kg/kg
\(1/SFR\) fuel per kg of steam kg/kg
\(GCV_{ar}\) GCV as fired J/kg
\(h_s - h_{fw}\) heat added per kg of steam J/kg

Method and standards

As-fired GCV from the dry value and moisture; steam from the useful heat with FireCAD's IAPWS-IF97 enthalpies.

Where it is used

  • Sugar mill steam and bagasse balances.
  • Biomass boiler fuel budgets.
  • Comparing high-pressure cogeneration boilers.

Common mistakes

  • Using a fixed efficiency for any moisture.
  • Mixing GCV and NCV.
  • Forgetting bagasse stored or bought in the balance.

Assumptions and limits

  • Ash in the dry GCV basis; efficiency entered for the actual moisture.
  • The heat per kg of steam is from feedwater to steam only; blowdown is not added (put it in the efficiency).
  • The steam pressure is absolute in every unit system: add the atmospheric pressure to a gauge reading.
  • The steam temperature is used only when superheated steam is chosen.

References

  • Input–output balance
  • IAPWS R7-97 IF97

Questions and answers

How much steam does a tonne of bagasse make?

Bagasse of 19.0 MJ/kg dry at 50 % moisture has 9.5 MJ/kg as fired; at 68 % efficiency, making 45 bar(a) / 400 °C steam from 140 °C feedwater, each kg gives 2.47 kg of steam (405 kg of bagasse per tonne).

Why does moisture matter twice?

It lowers the calorific value directly and also the efficiency, because the water must be evaporated and leaves up the stack.

What dry GCV should I use?

A lab value for your cane; it varies with variety and fibre content.

Method and article reviewed by FireCAD engineering on 11 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.