Worked example
Example: Bagasse 50 % moisture, 19.0 MJ/kg dry, 68 %, 45 bar(a) / 400 °C, feed 140 °C. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Gross calorific value, dry basis | 19,000 kJ/kg |
| Moisture as fired | 50.000 % |
| Boiler efficiency (on GCV) | 68.000 % |
| Steam pressure (absolute) | 45.000 bar |
| Steam condition | Superheated at the temperature below |
| Steam temperature (superheated only) | 400.00 °C |
| Feedwater temperature | 140.00 °C |
Applying the formula below gives:
| Result | Value |
|---|---|
| Steam per kg of fuel | 2.4716 kg/kg |
| Fuel per kg of steam | 404.59 kg/t |
| Gross calorific value as fired | 9,500.0 kJ/kg |
| Heat added per kg of steam | 2,613.7 kJ/kg |
Open this example in the calculator and change any input.
Formula
\(GCV_{ar} = GCV_d\,(1 - M) \qquad SFR = \frac{\eta\,GCV_{ar}}{h_s - h_{fw}} \qquad \frac{1}{SFR}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(GCV_d\) | gross calorific value, dry | J/kg |
| \(M\) | moisture as fired | – |
| \(\eta\) | boiler efficiency on GCV | – |
| \(p\) | steam pressure | Pa |
| \(\text{state}\) | saturated or superheated | – |
| \(T_s\) | steam temperature | K |
| \(T_{fw}\) | feedwater temperature | K |
| \(SFR\) | steam per kg of fuel | kg/kg |
| \(1/SFR\) | fuel per kg of steam | kg/kg |
| \(GCV_{ar}\) | GCV as fired | J/kg |
| \(h_s - h_{fw}\) | heat added per kg of steam | J/kg |
Method and standards
As-fired GCV from the dry value and moisture; steam from the useful heat with FireCAD's IAPWS-IF97 enthalpies.
Where it is used
- Sugar mill steam and bagasse balances.
- Biomass boiler fuel budgets.
- Comparing high-pressure cogeneration boilers.
Common mistakes
- Using a fixed efficiency for any moisture.
- Mixing GCV and NCV.
- Forgetting bagasse stored or bought in the balance.
Assumptions and limits
- Ash in the dry GCV basis; efficiency entered for the actual moisture.
- The heat per kg of steam is from feedwater to steam only; blowdown is not added (put it in the efficiency).
- The steam pressure is absolute in every unit system: add the atmospheric pressure to a gauge reading.
- The steam temperature is used only when superheated steam is chosen.
References
- Input–output balance
- IAPWS R7-97 IF97
Questions and answers
How much steam does a tonne of bagasse make?
Bagasse of 19.0 MJ/kg dry at 50 % moisture has 9.5 MJ/kg as fired; at 68 % efficiency, making 45 bar(a) / 400 °C steam from 140 °C feedwater, each kg gives 2.47 kg of steam (405 kg of bagasse per tonne).
Why does moisture matter twice?
It lowers the calorific value directly and also the efficiency, because the water must be evaporated and leaves up the stack.
What dry GCV should I use?
A lab value for your cane; it varies with variety and fibre content.
Method and article reviewed by FireCAD engineering on 11 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.