FireCADCalc

Steam from Biogas in a Boiler

Heat input and steam raised by burning biogas in a boiler from its flow, methane content, heating value and boiler efficiency, with IF97 enthalpies.

Distillery and ethanolIAPWS-IF97 (water and steam)Boiler

Inputs

Examples: 1500 Nm3/h at 58 %Small boiler

Results

H₂S in biogas forms SO₂ and acid dew point problems: scrub it before the boiler.

Heat input2.4662MW
Heat per kg of steam (dry saturated)2,432.8kJ/kg
Steam3.1021t/h

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 1500 Nm3/h at 58 %. The inputs, in the units selected above:

InputValue
Biogas1,500.0 Nm³/h
Methane in biogas58.000 %
Methane net heating value35.800 MJ/Nm³
Boiler efficiency (net basis)88.000 %
Steam pressure (absolute)11.000 bar
Feedwater temperature105.00 °C

Applying the formula below gives:

ResultValue
Heat input8.6517 MW
Heat per kg of steam (dry saturated)2,339.7 kJ/kg
Steam11.714 t/h

Open this example in the calculator and change any input.

Formula

\(\dot Q = \dot V_b y_{CH_4} LHV, \quad \dot m_s = \frac{\eta_b \dot Q}{h_g(p) - h(p, T_{fw})}\)

Variables

Symbol Meaning SI unit
\(\dot V_b\) Biogas Nm³/s
\(y_{CH_4}\) Methane in biogas -
\(LHV\) Methane net heating value J/m³
\(\eta_b\) Boiler efficiency (net basis) -
\(p\) Steam pressure (absolute) Pa
\(T_{fw}\) Feedwater temperature K
\(\dot Q\) Heat input W
\(\Delta h\) Heat per kg of steam (dry saturated) J/kg
\(\dot m_s\) Steam kg/s

Method and standards

Energy balance.

Where it is used

  • Biogas utilisation in distillery boilers.
  • Fuel saving reports.

Common mistakes

  • Gross efficiency with net heating value.

Assumptions and limits

  • Dry saturated steam.

References

  • Energy balance with IAPWS-IF97 enthalpies; methane LHV 35.8 MJ/Nm³ from 802.3 kJ/mol (NIST) by default

Questions and answers

Steam per Nm³ of biogas?

Roughly 7–8.5 kg of low-pressure steam at about 60 % methane.

Why net basis?

Biogas heating values are usually stated net; use the efficiency on the same basis.

Superheated steam?

Add the superheat enthalpy; this calculator takes dry saturated steam.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators