FireCADCalc

Thermocompression Limit by the Exhaust Balance

Most motive steam a thermocompressor can use before exhaust escapes, the vapour it then draws and the least vapour left for the condenser (Hugot 32.58–32.62).

Sugar mill and cogeneration

Inputs

Examples: QuadrupleQuintuple

Results

Beyond q_max the extra motive steam only pushes exhaust out of the roof; a regulator on exhaust pressure should hold the thermocompressor at or below it.

Most motive steam8,615.4kg/h
Vapour then aspirated12,923kg/h
Least vapour to the condenser11,615kg/h

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Quadruple. The inputs, in the units selected above:

InputValue
Number of effects4.0000 -
Entrainment ratio1.8000 -
Total evaporation80,000 kg/h
Vapour bled from effect 111,000 kg/h
Vapour bled from effect 23,500.0 kg/h
Vapour bled from effect 36,000.0 kg/h
Exhaust steam produced by the drives25,000 kg/h
Exhaust used by the pans4,000.0 kg/h
Exhaust used by the heaters3,000.0 kg/h

Applying the formula below gives:

ResultValue
Most motive steam9,310.3 kg/h
Vapour then aspirated16,759 kg/h
Least vapour to the condenser6,810.3 kg/h

Open this example in the calculator and change any input.

Formula

\(q \le \frac{E + (n-1)P_1 + (n-2)P_2 + (n-3)P_3 - n(M - C - R)}{n + \mu}, \quad y = \mu q\)

\(x \ge \frac{E - P_1 - 2P_2 - 3P_3 - \mu(P_1 + P_2 + P_3) + \mu(M - C - R)}{n + \mu}\)

Variables

Symbol Meaning SI unit
\(n\) Number of effects -
\(\mu\) Entrainment ratio -
\(E\) Total evaporation kg/s
\(P_1\) Vapour bled from effect 1 kg/s
\(P_2\) Vapour bled from effect 2 kg/s
\(P_3\) Vapour bled from effect 3 kg/s
\(M\) Exhaust steam produced by the drives kg/s
\(C\) Exhaust used by the pans kg/s
\(R\) Exhaust used by the heaters kg/s
\(q_{max}\) Most motive steam kg/s
\(y_{max}\) Vapour then aspirated kg/s
\(x_{min}\) Least vapour to the condenser kg/s

Method and standards

Hugot's exhaust balance with a first-effect thermocompressor.

Where it is used

  • Sizing and regulating thermocompressors.
  • Factory steam balances.

Common mistakes

  • Leaving pan vapour bleeding out of P.
  • Ignoring exhaust losses in M.

Assumptions and limits

  • Thermocompressor on the first effect.
  • Bleeding from effects 1 to 3 only (no P₄ input for 5 effects). With 3 effects P₃ is bled from the last effect: it does not change q_max but reduces the vapour to the condenser.
  • A negative x_min (bleeding beyond what the evaporator supplies) is rejected.

References

  • Hugot
  • Handbook of Cane Sugar Engineering
  • 3rd ed. (Elsevier, 1986)
  • ch. 32
  • installation of a thermo-compressor
  • eqns 32.52–32.62
  • pp. 603–606

Questions and answers

Why a limit?

Thermocompression saves make-up steam only until exhaust from the drives covers the factory; beyond that it wastes exhaust.

What are M, C and R?

Exhaust produced by turbines and engines, and the exhaust used by pans and heaters.

Why a minimum to the condenser?

With maximum thermocompression the later effects still need a minimum of vapour passing through.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.