FireCADCalc

Pre-Evaporator Evaporation Rate

Evaporation per m² and total of a pre-evaporator from its apparent temperature drop by Hugot's rates (eqns 32.32–32.33: 3.5Δt and 4.5Δt kg/m²/h).

Sugar mill and cogeneration

Inputs

Examples: Modern, 2000 m2, 12 °CPuerto Rico rate

Results

Pre-evaporators run at high temperature on clear juice and bleed most of their vapour to heaters and pans.

Evaporation per m²35.000kg/(m²·h)
Evaporation42,000kg/h

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Modern, 2000 m2, 12 °C. The inputs, in the units selected above:

InputValue
Heating surface2,000.0 m²
Apparent temperature drop12.000 K
Rate per degreeModern pre-evaporator (4.5)

Applying the formula below gives:

ResultValue
Evaporation per m²54.000 kg/(m²·h)
Evaporation108,000 kg/h

Open this example in the calculator and change any input.

Formula

\(\tau = k\,\Delta t\ [\mathrm{kg/(m^2\,h)}], \quad E = \tau S\)

Variables

Symbol Meaning SI unit
\(S\) Heating surface m²
\(\Delta t\) Apparent temperature drop K
\(k\) Rate per degree -
\(\tau\) Evaporation per m² kg/(m²·s)
\(E\) Evaporation kg/s

Method and standards

Hugot's empirical rates.

Where it is used

  • Sizing pre-evaporators.
  • Checking pre-evaporator output.

Common mistakes

  • Using the true drop with these rates.
  • Applying them to syrup effects.

Assumptions and limits

  • Clear juice of normal brix.
  • A linear rule in the apparent drop; no validity range is stated with it here, so large drops are extrapolations.

References

  • Hugot
  • Handbook of Cane Sugar Engineering
  • 3rd ed. (Elsevier, 1986)
  • ch. 32
  • pre-evaporators
  • eqns 32.32–32.33
  • pp. 576–580

Questions and answers

Why apparent drop?

Hugot's rule uses the drop between heating steam and vapour, which is easy to read in operation.

Why higher rates than a normal first effect?

Thin, hot juice boils freely; scale is lighter at the start of the set.

When is a pre-evaporator used?

When much vapour is wanted for heating and pans at a high temperature.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.