Worked example
Example: Modern, 2000 m2, 12 °C. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Heating surface | 2,000.0 m² |
| Apparent temperature drop | 12.000 K |
| Rate per degree | Modern pre-evaporator (4.5) |
Applying the formula below gives:
| Result | Value |
|---|---|
| Evaporation per m² | 54.000 kg/(m²·h) |
| Evaporation | 108,000 kg/h |
Open this example in the calculator and change any input.
Formula
\(\tau = k\,\Delta t\ [\mathrm{kg/(m^2\,h)}], \quad E = \tau S\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(S\) | Heating surface | m² |
| \(\Delta t\) | Apparent temperature drop | K |
| \(k\) | Rate per degree | - |
| \(\tau\) | Evaporation per m² | kg/(m²·s) |
| \(E\) | Evaporation | kg/s |
Method and standards
Hugot's empirical rates.
Where it is used
- Sizing pre-evaporators.
- Checking pre-evaporator output.
Common mistakes
- Using the true drop with these rates.
- Applying them to syrup effects.
Assumptions and limits
- Clear juice of normal brix.
- A linear rule in the apparent drop; no validity range is stated with it here, so large drops are extrapolations.
References
- Hugot
- Handbook of Cane Sugar Engineering
- 3rd ed. (Elsevier, 1986)
- ch. 32
- pre-evaporators
- eqns 32.32–32.33
- pp. 576–580
Questions and answers
Why apparent drop?
Hugot's rule uses the drop between heating steam and vapour, which is easy to read in operation.
Why higher rates than a normal first effect?
Thin, hot juice boils freely; scale is lighter at the start of the set.
When is a pre-evaporator used?
When much vapour is wanted for heating and pans at a high temperature.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.