Falling-Film Evaporator Wetting Rate

Wetting rate of a falling-film evaporator (juice per metre of tube circumference), juice per tube and the recirculation needed to reach the target (Hugot p. 620).

Sugar mill and cogenerationPump

Inputs

Examples: 100 t/h on 1800 tubesLast effect, low feed

Hugot: optimum 500–600 kg/(h·m), at most 1200–1500.

Results

Dry patches scale fast; recirculate juice when the feed alone cannot wet every tube.

Wetting rate, kg/(h·m)117.63
Juice per tube16.667kg/h
Recirculation to reach the target91.891t/h

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 100 t/h on 1800 tubes. The inputs, in the units selected above:

InputValue
Juice fed100.00 t/h
Number of tubes1,800.0 -
Tube diameter (wetted)45.100 mm
Target wetting rate, kg/(h·m)550.00 -

Applying the formula below gives:

ResultValue
Wetting rate, kg/(h·m)392.10
Juice per tube55.556 kg/h
Recirculation to reach the target40.269 t/h

Open this example in the calculator and change any input.

Formula

\(m = \frac{Q}{n\pi d}, \quad Q_r = m^* n\pi d - Q\)

Variables

Symbol Meaning SI unit
\(Q\) Juice fed kg/s
\(n\) Number of tubes -
\(d\) Tube diameter (wetted) m
\(m^*\) Target wetting rate, kg/(h·m) -
\(m\) Wetting rate, kg/(h·m) -
\(Q/n\) Juice per tube kg/s
\(Q_r\) Recirculation to reach the target kg/s

Method and standards

Definition of wetting rate as given by Hugot.

Where it is used

  • Designing falling-film effects.
  • Setting recirculation pumps.

Common mistakes

  • Using the outside diameter when the film is inside.
  • Ignoring evaporation along the tube in the last effects.

Assumptions and limits

  • Wetting at the top of the tubes.
  • Wetting rates are entered and shown in kg/(h·m) in every unit system. A note appears above Hugot's maximum of about 1500 kg/(h·m).

References

  • Hugot
  • Handbook of Cane Sugar Engineering
  • 3rd ed. (Elsevier, 1986)
  • ch. 32
  • falling-film evaporators (Longuet)
  • pp. 617–621

Questions and answers

Why does wetting matter?

A falling film must cover the whole tube; dry spots overheat, scale and lose sugar.

Typical tubes?

Hugot: stainless steel 45.1 × 48.3 mm, 7–10 m long.

Why no hydrostatic loss?

There is no liquid column; the film runs down the wall.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.