Worked example
Example: 100 t/h on 1800 tubes. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Juice fed | 100.00 t/h |
| Number of tubes | 1,800.0 - |
| Tube diameter (wetted) | 45.100 mm |
| Target wetting rate, kg/(h·m) | 550.00 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| Wetting rate, kg/(h·m) | 392.10 |
| Juice per tube | 55.556 kg/h |
| Recirculation to reach the target | 40.269 t/h |
Open this example in the calculator and change any input.
Formula
\(m = \frac{Q}{n\pi d}, \quad Q_r = m^* n\pi d - Q\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(Q\) | Juice fed | kg/s |
| \(n\) | Number of tubes | - |
| \(d\) | Tube diameter (wetted) | m |
| \(m^*\) | Target wetting rate, kg/(h·m) | - |
| \(m\) | Wetting rate, kg/(h·m) | - |
| \(Q/n\) | Juice per tube | kg/s |
| \(Q_r\) | Recirculation to reach the target | kg/s |
Method and standards
Definition of wetting rate as given by Hugot.
Where it is used
- Designing falling-film effects.
- Setting recirculation pumps.
Common mistakes
- Using the outside diameter when the film is inside.
- Ignoring evaporation along the tube in the last effects.
Assumptions and limits
- Wetting at the top of the tubes.
- Wetting rates are entered and shown in kg/(h·m) in every unit system. A note appears above Hugot's maximum of about 1500 kg/(h·m).
References
- Hugot
- Handbook of Cane Sugar Engineering
- 3rd ed. (Elsevier, 1986)
- ch. 32
- falling-film evaporators (Longuet)
- pp. 617–621
Questions and answers
Why does wetting matter?
A falling film must cover the whole tube; dry spots overheat, scale and lose sugar.
Typical tubes?
Hugot: stainless steel 45.1 × 48.3 mm, 7–10 m long.
Why no hydrostatic loss?
There is no liquid column; the film runs down the wall.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.