FireCADCalc

Evaporator Vapour Pipe Size

Diameter of a vapour pipe between evaporator effects from the vapour flow, its saturation temperature (IF97 specific volume) and Hugot's velocities (Table 32.7).

Sugar mill and cogenerationIAPWS-IF97 (water and steam)

Inputs

Examples: Hugot: 20 000 kg/h at 103 °C, 25 m/sLast effect to condenser

Hugot: exhaust 25–30 m/s; quadruple vapours 30–35, 35–40, 40–45, 50–60 m/s; to the condenser up to 75.

Results

Hugot's example: 20 000 kg/h at 103 °C and 25 m/s needs about 0.37 m², a 700 mm pipe.

Specific volume of the vapour9.5649m³/kg
Vapour volume flow32.149m³/s
Pipe area0.53581m²
Pipe diameter825.96mm

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Hugot: 20 000 kg/h at 103 °C, 25 m/s. The inputs, in the units selected above:

InputValue
Vapour flow20,000 kg/h
Vapour saturation temperature103.00 °C
Vapour velocity25.000 m/s
Margin on flow1.1000 -

Applying the formula below gives:

ResultValue
Specific volume of the vapour1.5140 m³/kg
Vapour volume flow9.2519 m³/s
Pipe area0.37008 m²
Pipe diameter686.44 mm

Open this example in the calculator and change any input.

Formula

\(\dot V = k P v''(T), \quad A = \frac{\dot V}{V}, \quad D = \sqrt{\frac{4A}{\pi}}\)

Variables

Symbol Meaning SI unit
\(P\) Vapour flow kg/s
\(T\) Vapour saturation temperature K
\(V\) Vapour velocity m/s
\(k\) Margin on flow -
\(v''\) Specific volume of the vapour m³/kg
\(\dot V\) Vapour volume flow m³/s
\(A\) Pipe area m²
\(D\) Pipe diameter m

Method and standards

Continuity with IF97 specific volume.

Where it is used

  • Evaporator and pan vapour piping.
  • Checking existing pipes after a crush increase.

Common mistakes

  • Using liquid specific volume.
  • Ignoring bleeding in the flow.

Assumptions and limits

  • Saturated vapour.
  • The velocity you enter is not checked against Hugot's ranges for each effect (given in the help), and no pressure drop is computed: check long lines separately.

References

  • Hugot
  • Handbook of Cane Sugar Engineering
  • 3rd ed. (Elsevier, 1986)
  • ch. 32
  • steam and vapour pipes
  • Table 32.7 and example
  • pp. 513–515
  • Specific volume from IAPWS-IF97

Questions and answers

Why higher velocities in later effects?

Vapour at low pressure has a huge volume; higher velocities keep pipes affordable, and the pressure loss matters less in absolute terms.

Why a 10 % margin?

Hugot adds it to cover peaks and bleeding changes.

Pressure drop?

Check long lines separately: a drop of pressure is a loss of temperature difference.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.