FireCADCalc

Hydrostatic Head and Boiling Temperature in the Tubes

Rise of boiling temperature at the mean depth of juice in evaporator tubes from tube length, juice level and density, with IF97 saturation (Hugot ch. 32).

Sugar mill and cogenerationIAPWS-IF97 (water and steam)

Inputs

Examples: Last effect, 2.25 m tubesFirst effect

Hugot: optimum 30–40 % of tube height; Kestner about 20 %.

Results

The rise is small in the first effect and several degrees in the last, where the pressure is low and the syrup dense.

Mean depth0.70000m
Pressure at the mean depth207.28kPa
Rise of boiling temperature1.1335K

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Last effect, 2.25 m tubes. The inputs, in the units selected above:

InputValue
Pressure in the vapour space (absolute)16.000 kPa
Tube length2.2500 m
Juice level as a share of tube height33.000 %
Juice density1,250.0 kg/m³

Applying the formula below gives:

ResultValue
Mean depth0.37125 m
Pressure at the mean depth20.551 kPa
Rise of boiling temperature5.3333 K

Open this example in the calculator and change any input.

Formula

\(z = \frac{\ell L}{2}, \quad p_m = p + \rho g z, \quad \Delta T_h = T_s(p_m) - T_s(p)\)

Variables

Symbol Meaning SI unit
\(p\) Pressure in the vapour space (absolute) Pa
\(L\) Tube length m
\(\ell\) Juice level as a share of tube height -
\(\rho\) Juice density kg/m³
\(z\) Mean depth m
\(p_m\) Pressure at the mean depth Pa
\(\Delta T_h\) Rise of boiling temperature K
\(g\) Standard gravity, 9.806 65 m/s²
\(T_s\) Saturation temperature of water (IAPWS-IF97) K

Method and standards

Hydrostatics with IF97 saturation.

Where it is used

  • Evaporator temperature balances.
  • Choosing juice levels.

Common mistakes

  • Taking the full tube length as the head.
  • Using water density for syrup.

Assumptions and limits

  • Liquid column without bubbles (conservative).

References

  • Hugot
  • Handbook of Cane Sugar Engineering
  • 3rd ed. (Elsevier, 1986)
  • ch. 32
  • hydrostatic pressure
  • pp. 497–504
  • Saturation temperature from IAPWS-IF97

Questions and answers

Why the mean depth?

Boiling starts where pressure allows; Hugot takes the juice at mean depth, half the level, as representative.

Why does the last effect lose most?

At 15–20 kPa a small head changes the saturation temperature far more than at 200 kPa.

How do falling-film evaporators help?

They have no liquid column, so no hydrostatic loss.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.