FireCADCalc

Evaporator Body Heating Surface

Heating surface of one evaporator or pan body from its evaporation, the heating and body pressures, the boiling-point elevation and the overall coefficient (IF97).

Sugar mill and cogenerationDistillery and ethanolIAPWS-IF97 (water and steam)

Inputs

Examples: First bodySyrup body

Results

Juice is taken entering at its boiling point; U falls from the first to the last body as brix rises.

Useful temperature difference19.401K
Heat duty16,452kW
Heating surface1,211.5m²
Heating steam or vapour condensed25.625t/h

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: First body. The inputs, in the units selected above:

InputValue
Evaporation in this body40.000 t/h
Heating steam or vapour pressure (absolute)2.0000 bar
Body (vapour space) pressure (absolute)1.6000 bar
Boiling-point elevation0.50000 K
Overall heat-transfer coefficient2,500.0 W/(m²·K)

Applying the formula below gives:

ResultValue
Useful temperature difference6.4133 K
Heat duty24,675 kW
Heating surface1,538.9 m²
Heating steam or vapour condensed40.348 t/h

Open this example in the calculator and change any input.

Formula

\(\Delta T = T_{sat}(p_h) - [T_{sat}(p_b) + BPE], \quad \dot Q = E\,h_{fg}(p_b), \quad A = \frac{\dot Q}{U \Delta T}\)

Variables

Symbol Meaning SI unit
\(E\) Evaporation in this body kg/s
\(p_h\) Heating steam or vapour pressure (absolute) Pa
\(p_b\) Body (vapour space) pressure (absolute) Pa
\(BPE\) Boiling-point elevation K
\(U\) Overall heat-transfer coefficient W/(m²·K)
\(\Delta T\) Useful temperature difference K
\(\dot Q\) Heat duty W
\(A\) Heating surface m²
\(\dot m_s\) Heating steam or vapour condensed kg/s

Method and standards

Energy balance.

Where it is used

  • Evaporator design and debottlenecking.

Common mistakes

  • BPE left out in the syrup body.

Assumptions and limits

  • Feed at boiling point and no heat loss: for a colder feed, or with losses, more steam is condensed than shown; flash from a hotter feed reduces it.
  • For a pan the same balance is used, with no massecuite-specific terms (crystallisation heat, changing level and brix).

References

  • Q = U A ΔT with boiling-point elevation; latent heats from IAPWS-IF97

Questions and answers

What is the useful temperature difference?

Heating steam saturation temperature less the boiling temperature of the juice, BPE included.

Which U?

Plant data by body: high in the first body, low in the syrup body.

Hydrostatic head?

It raises the boiling point at the tube bottom; add it to the BPE for tall tubes.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.