FireCADCalc

Evaporator Heat Losses and the Evaporation They Cost

Heat lost from the walls of each evaporator vessel, the vapour it condenses, and the evaporation lost in the later effects by Hugot's place weighting (ch. 32).

Sugar mill and cogenerationIAPWS-IF97 (water and steam)

Inputs

Examples: Lagged quadrupleBare quintuple

Hugot (Sandera): about 1.6 kcal/(m²·h·°C) for vessels lagged with 60 mm; bare metal several times more.

Results

A loss in the first vessel costs most: the vapour it condenses would have evaporated again in every later effect (Hugot's weighting n − i).

Total heat loss299.59kW
Vapour condensed by the losses475.68kg/h
Evaporation lost in later effects1,160.7kg/h

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Lagged quadruple. The inputs, in the units selected above:

InputValue
Number of effects4.0000 -
Exposed surface of each vessel80.000 m²
Loss coefficient (surface to air)1.8608 W/(m²·K)
Ambient temperature30.000 °C
Temperature of vessel 1104.00 °C
Temperature of vessel 294.000 °C
Temperature of vessel 380.000 °C
Temperature of vessel 455.000 °C
Temperature of vessel 555.000 °C

Applying the formula below gives:

ResultValue
Total heat loss31.708 kW
Vapour condensed by the losses50.016 kg/h
Evaporation lost in later effects94.773 kg/h

Open this example in the calculator and change any input.

Formula

\(\dot Q_i = U A (T_i - T_a), \quad \dot m_i = \frac{\dot Q_i}{h_{fg}(T_i)}, \quad \text{evaporation lost} = \sum (n - i)\dot m_i\)

Variables

Symbol Meaning SI unit
\(n\) Number of effects -
\(A\) Exposed surface of each vessel m²
\(U\) Loss coefficient (surface to air) W/(m²·K)
\(T_a\) Ambient temperature K
\(T_1\) Temperature of vessel 1 K
\(T_2\) Temperature of vessel 2 K
\(T_3\) Temperature of vessel 3 K
\(T_4\) Temperature of vessel 4 K
\(T_5\) Temperature of vessel 5 K
\(\dot Q\) Total heat loss W
\(\Sigma\dot m_i\) Vapour condensed by the losses kg/s
\(\Sigma(n - i)\dot m_i\) Evaporation lost in later effects kg/s

Method and standards

Wall losses and Hugot's place weighting.

Where it is used

  • Justifying lagging.
  • Evaporator steam balances.

Common mistakes

  • Using bare-pipe coefficients for lagged vessels.
  • Ignoring the place weighting.

Assumptions and limits

  • Uniform surface temperature.
  • The cost is expressed as evaporation lost, not money or fuel. Vessel temperatures must fall along the set.

References

  • Hugot
  • Handbook of Cane Sugar Engineering
  • 3rd ed. (Elsevier, 1986)
  • ch. 32
  • heat losses (Sandera, Kerr and Webre)
  • pp. 543–545
  • Latent heat from IAPWS-IF97

Questions and answers

How big are the losses?

Hugot: 2–5 % of the steam for a well-lagged quadruple, up to 10 % unlagged.

Why weight by n − i?

Vapour condensed in vessel i is missing from the heating of vessel i + 1 and all after it.

Which temperature?

The temperature of the juice and vapour in each vessel.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.