FireCADCalc

Evaporator Chemical Cleaning: Caustic and Acid

Caustic soda and hydrochloric acid for boiling out an evaporator vessel at chosen strengths, as commercial products, with the inhibitor (after Hugot ch. 32).

Sugar mill and cogeneration

Inputs

Examples: 20 m3, 5 % soda, 2 % acidLarge vessel, lye

Hugot: 2–5 % (Java); 4 % (USA); stronger in some countries.
Hugot: start at about 2.5 %, never above 2 % in long contact; 1–2 % usual.
Hugot: 6 L of formalin per 100 kg HCl.

Results

Hugot: soda boil 3–4 h, rinse, then acid about 1 h with inhibitor; soda can be reused about a dozen times.

NaOH (100 %)3,456.0kg
Commercial soda7,200.0kg
HCl (100 %)648.00kg
Commercial acid1,692.8L
Inhibitor38.880L

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 20 m3, 5 % soda, 2 % acid. The inputs, in the units selected above:

InputValue
Solution volume in the vessel20.000 m³
Solution density1,050.0 kg/m³
Caustic strength (NaOH)5.0000 %
NaOH in the commercial soda98.000 %
Acid strength (HCl)2.0000 %
HCl in the commercial acid30.000 %
Commercial acid density1,150.0 kg/m³
Inhibitor per 100 kg HCl6.0000 L

Applying the formula below gives:

ResultValue
NaOH (100 %)1,050.0 kg
Commercial soda1,071.4 kg
HCl (100 %)420.00 kg
Commercial acid1,217.4 L
Inhibitor25.200 L

Open this example in the calculator and change any input.

Formula

\(m_{NaOH} = V\rho w_c, \quad m_s = \frac{m_{NaOH}}{p_c}, \quad m_{HCl} = V\rho w_a, \quad V_a = \frac{m_{HCl}}{p_a\rho_a}, \quad V_i = \frac{m_{HCl}}{100}i\)

Variables

Symbol Meaning SI unit
\(V\) Solution volume in the vessel m³
\(\rho\) Solution density kg/m³
\(w_c\) Caustic strength (NaOH) -
\(p_c\) NaOH in the commercial soda -
\(w_a\) Acid strength (HCl) -
\(p_a\) HCl in the commercial acid -
\(\rho_a\) Commercial acid density kg/m³
\(i\) Inhibitor per 100 kg HCl m³
\(m_{NaOH}\) NaOH (100 %) kg
\(m_s\) Commercial soda kg
\(m_{HCl}\) HCl (100 %) kg
\(V_a\) Commercial acid m³
\(V_i\) Inhibitor m³

Method and standards

Solution make-up.

Where it is used

  • Planning weekly or seasonal cleaning.
  • Chemical stocks.

Common mistakes

  • Using commercial weight as 100 %.
  • Too strong acid on brass tubes.

Assumptions and limits

  • Batch made up to volume.
  • One solution density is used for both the caustic and the acid solution; the commercial acid density is entered separately and should match its strength (about 1150 kg/m³ for 30 % HCl).
  • A note appears for acid above 2 %.

References

  • Hugot
  • Handbook of Cane Sugar Engineering
  • 3rd ed. (Elsevier, 1986)
  • ch. 32
  • chemical cleaning
  • pp. 546–550

Questions and answers

Why soda first?

Caustic converts calcium sulphate and organic scale to forms acid can dissolve.

Why an inhibitor?

It protects steel and brass from the acid during contact.

How strong?

Practice varies widely; Hugot cites 2–5 % soda and 1–2 % acid with care not to attack tubes.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.