Worked example
Example: 20 m3, 5 % soda, 2 % acid. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Solution volume in the vessel | 20.000 m³ |
| Solution density | 1,050.0 kg/m³ |
| Caustic strength (NaOH) | 5.0000 % |
| NaOH in the commercial soda | 98.000 % |
| Acid strength (HCl) | 2.0000 % |
| HCl in the commercial acid | 30.000 % |
| Commercial acid density | 1,150.0 kg/m³ |
| Inhibitor per 100 kg HCl | 6.0000 L |
Applying the formula below gives:
| Result | Value |
|---|---|
| NaOH (100 %) | 1,050.0 kg |
| Commercial soda | 1,071.4 kg |
| HCl (100 %) | 420.00 kg |
| Commercial acid | 1,217.4 L |
| Inhibitor | 25.200 L |
Open this example in the calculator and change any input.
Formula
\(m_{NaOH} = V\rho w_c, \quad m_s = \frac{m_{NaOH}}{p_c}, \quad m_{HCl} = V\rho w_a, \quad V_a = \frac{m_{HCl}}{p_a\rho_a}, \quad V_i = \frac{m_{HCl}}{100}i\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(V\) | Solution volume in the vessel | m³ |
| \(\rho\) | Solution density | kg/m³ |
| \(w_c\) | Caustic strength (NaOH) | - |
| \(p_c\) | NaOH in the commercial soda | - |
| \(w_a\) | Acid strength (HCl) | - |
| \(p_a\) | HCl in the commercial acid | - |
| \(\rho_a\) | Commercial acid density | kg/m³ |
| \(i\) | Inhibitor per 100 kg HCl | m³ |
| \(m_{NaOH}\) | NaOH (100 %) | kg |
| \(m_s\) | Commercial soda | kg |
| \(m_{HCl}\) | HCl (100 %) | kg |
| \(V_a\) | Commercial acid | m³ |
| \(V_i\) | Inhibitor | m³ |
Method and standards
Solution make-up.
Where it is used
- Planning weekly or seasonal cleaning.
- Chemical stocks.
Common mistakes
- Using commercial weight as 100 %.
- Too strong acid on brass tubes.
Assumptions and limits
- Batch made up to volume.
- One solution density is used for both the caustic and the acid solution; the commercial acid density is entered separately and should match its strength (about 1150 kg/m³ for 30 % HCl).
- A note appears for acid above 2 %.
References
- Hugot
- Handbook of Cane Sugar Engineering
- 3rd ed. (Elsevier, 1986)
- ch. 32
- chemical cleaning
- pp. 546–550
Questions and answers
Why soda first?
Caustic converts calcium sulphate and organic scale to forms acid can dissolve.
Why an inhibitor?
It protects steel and brass from the acid during contact.
How strong?
Practice varies widely; Hugot cites 2–5 % soda and 1–2 % acid with care not to attack tubes.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.