FireCADCalc

Evaporator Capacity from Installed Surface

Evaporation a multiple effect gives from its total surface by Hugot's rule (about 100/n kg/m²/h), against the evaporation needed, and surface per t cane/h.

Sugar mill and cogeneration

Inputs

Examples: Quadruple 2000 m2Quintuple with losses factor

Hugot Table 32.21 shows about 1.2 with heat losses allowed for 2.4 m tubes; Webre's figures are higher still.

Results

The evaporation needed is 142 % of what the surface gives by Hugot's rule: the evaporator is undersized for this juice, or needs higher temperatures or more bleeding to cope.

Hugot: about 24 m² per t cane/h for a quadruple at 1 kg/cm² back-pressure (17 triple, 31 quintuple); more at lower back-pressure.

Evaporation per m² of total surface24.000kg/(m²·h)
Evaporation capacity84,000kg/h
Evaporation needed119,118kg/h
Load on the evaporator141.81%
Surface per t cane/h (m² per t/h)23.333m²

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Quadruple 2000 m2. The inputs, in the units selected above:

InputValue
Number of effects4.0000 -
Total heating surface2,000.0 m²
Factor on Hugot's rate1.0000 -
Crushing rate100.00 t/h
Clear juice100.00 t/h
Clear juice brix13.000 %
Syrup brix65.000 %

Applying the formula below gives:

ResultValue
Evaporation per m² of total surface25.000 kg/(m²·h)
Evaporation capacity50,000 kg/h
Evaporation needed80,000 kg/h
Load on the evaporator160.00 %
Surface per t cane/h (m² per t/h)20.000 m²

Open this example in the calculator and change any input.

Formula

\(g = k\frac{100}{n}\ \mathrm{kg/(m^2\,h)}, \quad E_c = g S, \quad E = J\left(1 - \frac{B_0}{B_s}\right)\)

Variables

Symbol Meaning SI unit
\(n\) Number of effects -
\(S\) Total heating surface m²
\(k\) Factor on Hugot's rate -
\(A\) Crushing rate kg/s
\(J\) Clear juice kg/s
\(B_0\) Clear juice brix -
\(B_s\) Syrup brix -
\(g\) Evaporation per m² of total surface kg/(m²·s)
\(E_c\) Evaporation capacity kg/s
\(E\) Evaporation needed kg/s
\(E/E_c\) Load on the evaporator -
\(S/A\) Surface per t cane/h m² per t/h

Method and standards

Hugot's rule of thumb.

Where it is used

  • Quick evaporator checks.
  • Planning crush expansions.

Common mistakes

  • Comparing with surfaces measured outside the tubes.
  • Ignoring the pre-evaporator.

Assumptions and limits

  • Normal temperatures; moderate bleeding. Vapour bleeding and a pre-evaporator are not modelled.
  • Crushing rate and clear juice are separate inputs and are not checked against each other; the crushing rate is used only for the surface per t cane/h.
  • A note appears when the load exceeds 100 %.

References

  • Hugot
  • Handbook of Cane Sugar Engineering
  • 3rd ed. (Elsevier, 1986)
  • ch. 32
  • rule for evaporation and Tables 32.17
  • 32.21
  • 32.32–32.33
  • pp. 578–580 and 608–609

Questions and answers

Where does 100/n come from?

Hugot's rule: a set of equal vessels evaporates about 100 kg/h per m² of one vessel, so 100/n per m² of the whole set.

Is it accurate?

It is a first check; use the design calculation for real temperatures and bleeding.

Why does bleeding change it?

Bleeding moves evaporation to the first vessels, which work harder; the totals stay close.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.