Worked example
Example: Quadruple 2000 m2. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Number of effects | 4.0000 - |
| Total heating surface | 2,000.0 m² |
| Factor on Hugot's rate | 1.0000 - |
| Crushing rate | 100.00 t/h |
| Clear juice | 100.00 t/h |
| Clear juice brix | 13.000 % |
| Syrup brix | 65.000 % |
Applying the formula below gives:
| Result | Value |
|---|---|
| Evaporation per m² of total surface | 25.000 kg/(m²·h) |
| Evaporation capacity | 50,000 kg/h |
| Evaporation needed | 80,000 kg/h |
| Load on the evaporator | 160.00 % |
| Surface per t cane/h (m² per t/h) | 20.000 m² |
Open this example in the calculator and change any input.
Formula
\(g = k\frac{100}{n}\ \mathrm{kg/(m^2\,h)}, \quad E_c = g S, \quad E = J\left(1 - \frac{B_0}{B_s}\right)\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(n\) | Number of effects | - |
| \(S\) | Total heating surface | m² |
| \(k\) | Factor on Hugot's rate | - |
| \(A\) | Crushing rate | kg/s |
| \(J\) | Clear juice | kg/s |
| \(B_0\) | Clear juice brix | - |
| \(B_s\) | Syrup brix | - |
| \(g\) | Evaporation per m² of total surface | kg/(m²·s) |
| \(E_c\) | Evaporation capacity | kg/s |
| \(E\) | Evaporation needed | kg/s |
| \(E/E_c\) | Load on the evaporator | - |
| \(S/A\) | Surface per t cane/h | m² per t/h |
Method and standards
Hugot's rule of thumb.
Where it is used
- Quick evaporator checks.
- Planning crush expansions.
Common mistakes
- Comparing with surfaces measured outside the tubes.
- Ignoring the pre-evaporator.
Assumptions and limits
- Normal temperatures; moderate bleeding. Vapour bleeding and a pre-evaporator are not modelled.
- Crushing rate and clear juice are separate inputs and are not checked against each other; the crushing rate is used only for the surface per t cane/h.
- A note appears when the load exceeds 100 %.
References
- Hugot
- Handbook of Cane Sugar Engineering
- 3rd ed. (Elsevier, 1986)
- ch. 32
- rule for evaporation and Tables 32.17
- 32.21
- 32.32–32.33
- pp. 578–580 and 608–609
Questions and answers
Where does 100/n come from?
Hugot's rule: a set of equal vessels evaporates about 100 kg/h per m² of one vessel, so 100/n per m² of the whole set.
Is it accurate?
It is a first check; use the design calculation for real temperatures and bleeding.
Why does bleeding change it?
Bleeding moves evaporation to the first vessels, which work harder; the totals stay close.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.