Worked example
Example: 14.5 to 65 brix. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Clear juice flow (by mass) | 255.00 t/h |
| Clear juice brix | 14.500 % |
| Syrup brix | 65.000 % |
Applying the formula below gives:
| Result | Value |
|---|---|
| Syrup | 56.885 t/h |
| Water evaporated | 198.12 t/h |
| Evaporation % juice | 77.692 % |
Open this example in the calculator and change any input.
Formula
\(\dot m_s = \dot m_j \frac{Bx_1}{Bx_2}, \quad E = \dot m_j - \dot m_s\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\dot m_j\) | Clear juice flow (by mass) | kg/s |
| \(Bx_1\) | Clear juice brix | - |
| \(Bx_2\) | Syrup brix | - |
| \(\dot m_s\) | Syrup | kg/s |
| \(E\) | Water evaporated | kg/s |
| \(E/\dot m_j\) | Evaporation % juice | - |
Method and standards
Solids balance.
Where it is used
- Evaporator station design.
- Steam balance.
Common mistakes
- Mixed juice brix used instead of clear.
Assumptions and limits
- No solids lost.
- The juice flow is by mass. A flowmeter reading in m³/h must be multiplied by the juice density (about 1.06 t/m³ at 15 brix) first, or the evaporation is understated by about 6 %.
References
- Solids balance ṁ₁ Bx₁ = ṁ₂ Bx₂
Questions and answers
Why is evaporation about 80 % of juice?
Juice at about 15 brix becomes syrup at 60–65 brix: most of the water must go.
Does imbibition raise it?
Yes, every tonne of added water is evaporated here.
Higher syrup brix?
Less pan evaporation, but risk of crystallisation in the last body.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.