FireCADCalc

Molecular Sieve: Water Load and Regeneration Heat

Water a molecular sieve removes, desiccant per bed for a cycle at a water loading, and heat of desorption at 1 800 BTU/lb (Alcohol Textbook ch. 23).

Distillery and ethanol

Inputs

Examples: 10 t/h anhydrous, 92.5 % feed190 proof feed

Type 3A sieve can hold up to 22 % of its weight; pressure-swing units run far lower to limit the temperature swing.
Alcohol Textbook: 1 800 BTU per lb of water = 4 186.8 kJ/kg.

Results

Part of the dry product (often a fifth to a third) is used to purge the regenerating bed and returns to the rectifier; the feed here excludes that recycle.

The heat shown is the whole heat of desorption, not the external heat demand: much of it comes from heat stored in the bed during adsorption.

Feed vapour5,395.0kg/h
Water removed395.02kg/h
Water adsorbed per cycle32.918kg
Desiccant per bed329.18kg
Heat of desorption of the water removed459.41kW

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 10 t/h anhydrous, 92.5 % feed. The inputs, in the units selected above:

InputValue
Anhydrous ethanol product10,000 kg/h
Ethanol in the feed vapour (mass)92.500 %
Water allowed in the product (mass)0.20000 %
Adsorption period per bed6.0000 min
Working water loading of the sieve8.0000 %
Heat of desorption4,186.8 kJ/kg

Applying the formula below gives:

ResultValue
Feed vapour10,789 kg/h
Water removed789.19 kg/h
Water adsorbed per cycle78.919 kg
Desiccant per bed986.49 kg
Heat of desorption of the water removed917.83 kW

Open this example in the calculator and change any input.

Formula

\(\dot m_f = \frac{\dot m_E(1 - x_p)}{x_f}, \quad \dot m_w = \dot m_f - \dot m_E, \quad m_s = \frac{\dot m_w t_c}{q}, \quad \dot Q = \dot m_w\Delta h_d\)

Variables

Symbol Meaning SI unit
\(\dot m_E\) Anhydrous ethanol product kg/s
\(x_f\) Ethanol in the feed vapour (mass) -
\(x_p\) Water allowed in the product (mass) -
\(t_c\) Adsorption period per bed s
\(q\) Working water loading of the sieve -
\(\Delta h_d\) Heat of desorption J/kg
\(\dot m_f\) Feed vapour kg/s
\(\dot m_w\) Water removed kg/s
\(m_{w,c}\) Water adsorbed per cycle kg
\(m_s\) Desiccant per bed kg
\(\dot Q\) Heat of desorption of the water removed W

Method and standards

Mass balance and the heat of desorption.

Where it is used

  • Sizing sieve beds.
  • Understanding temperature swings.

Common mistakes

  • Using volume % for mass fractions.
  • Counting the purge recycle as product.

Assumptions and limits

  • Water removed only by adsorption.
  • The heat is the full heat of desorption of the water removed, not the external heat to supply: much of it is the heat stored in the bed during adsorption.

References

  • Jacques
  • Lyons and Kelsall (eds.)
  • The Alcohol Textbook
  • 4th ed. (Nottingham University Press, 2003)
  • ch. 23 (Swain)
  • development and operation of the molecular sieve
  • Mass balance of ethanol and water

Questions and answers

Why does the bed heat up?

Adsorbing water releases about 1 800 BTU per lb; the bed warms while drying and cools while regenerating.

Why not load the sieve fully?

A full 22 % load would swing the temperature too far; short cycles at low loading keep it steady.

Where does the regeneration heat come from?

Largely from the heat stored in the bed during adsorption; the vacuum purge carries the water away.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.