FireCADCalc

Molecular Sieve Bed Mass and Volume per Cycle

Adsorbent mass and bed volume for one bed from the water removed per hour, the cycle time and the working adsorption capacity of the sieve.

Distillery and ethanol

Inputs

Examples: 0.25 t/h water, 10 minLarger unit

Results

Working capacity is well below the equilibrium capacity of 3A sieve; use the supplier's design figure.

Water per cycle66.667kg
Sieve per bed0.66667t
Bed volume0.98039m³

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 0.25 t/h water, 10 min. The inputs, in the units selected above:

InputValue
Water removed0.25000 t/h
Adsorption time per bed10.000 min
Working capacity (kg water per kg sieve)0.080000 kg/kg
Sieve bulk density700.00 kg/m³

Applying the formula below gives:

ResultValue
Water per cycle41.667 kg
Sieve per bed0.52083 t
Bed volume0.74405 m³

Open this example in the calculator and change any input.

Formula

\(m_s = \frac{\dot m_w t_c}{q}, \quad V = \frac{m_s}{\rho_b}\)

Variables

Symbol Meaning SI unit
\(\dot m_w\) Water removed kg/s
\(t_c\) Adsorption time per bed s
\(q\) Working capacity (kg water per kg sieve) kg/kg
\(\rho_b\) Sieve bulk density kg/m³
\(m_w\) Water per cycle kg
\(m_s\) Sieve per bed kg
\(V\) Bed volume m³

Method and standards

Mass balance.

Where it is used

  • MSDH sizing and sieve replacement.

Common mistakes

  • Equilibrium capacity used.

Assumptions and limits

  • Constant water load.

References

  • Adsorption mass balance m_s = ṁ_w t_c / q

Questions and answers

Why 3A sieve?

Its pores admit water but not ethanol.

Working capacity?

Much less than equilibrium because beds switch before breakthrough and do not fully regenerate.

Two beds?

One adsorbs while the other regenerates; size each for one cycle.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.