FireCADCalc

Ethanol–Water Boiling Point and Vapour Strength (x–y)

Boiling point, vapour composition and condensed vapour strength of an ethanol–water liquid near 1 atm, with the azeotrope, by a Wilson model fitted to x–y data.

Distillery and ethanolIAPWS-IF97 (water and steam)

Inputs

Examples: 8 % vol washPerry/DECHEMA point x = 0.1050 % mass

Model fitted at 1 atm; use 0.9–1.2 atm.

Results

Above the azeotrope (about 0.885 mole fraction, about 97 % vol) ordinary distillation cannot enrich ethanol further.

Liquid mole fraction of ethanol10.000%
Boiling (bubble) point86.457°C
Vapour mole fraction of ethanol43.767%
Strength of the condensed vapour73.857%
Relative volatility ethanol/water7.0050
Activity coefficient of ethanol3.2033
Activity coefficient of water1.0336
Azeotrope mole fraction at this pressure88.544%

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 8 % vol wash. The inputs, in the units selected above:

InputValue
Liquid strength entered as% vol at 20 °C
Liquid strength8.0000 %
Pressure101.33 kPa

Applying the formula below gives:

ResultValue
Liquid mole fraction of ethanol2.6025 %
Boiling (bubble) point93.518 °C
Vapour mole fraction of ethanol22.788 %
Strength of the condensed vapour50.624 %
Relative volatility ethanol/water11.046
Activity coefficient of ethanol4.9547
Activity coefficient of water1.0029
Azeotrope mole fraction at this pressure88.544 %

Open this example in the calculator and change any input.

Formula

\(y_1 P = x_1\gamma_1 p_1^s(T), \quad y_2 P = x_2\gamma_2 p_2^s(T), \quad \ln\gamma_1 = -\ln(x_1 + \Lambda_{12}x_2) + x_2\left(\frac{\Lambda_{12}}{x_1 + \Lambda_{12}x_2} - \frac{\Lambda_{21}}{x_2 + \Lambda_{21}x_1}\right)\)

\(\Lambda_{12} = \frac{V_2}{V_1}e^{-a_{12}/RT}, \quad \Lambda_{21} = \frac{V_1}{V_2}e^{-a_{21}/RT}\)

Variables

Symbol Meaning SI unit
\(\text{basis}\) Liquid strength entered as -
\(s\) Liquid strength -
\(P\) Pressure Pa
\(x_1\) Liquid mole fraction of ethanol -
\(T_b\) Boiling (bubble) point K
\(y_1\) Vapour mole fraction of ethanol -
\(q_y\) Strength of the condensed vapour -
\(\alpha\) Relative volatility ethanol/water -
\(\gamma_1\) Activity coefficient of ethanol -
\(\gamma_2\) Activity coefficient of water -
\(x_{az}\) Azeotrope mole fraction at this pressure -
\(\gamma_1, \gamma_2\) Activity coefficients of ethanol and water (Wilson) -
\(p_1^s, p_2^s\) Vapour pressures of ethanol and water Pa
\(\Lambda_{12}, \Lambda_{21}, a_{12}, a_{21}\) Wilson parameters (399 and 933 cal/mol; V₁ 58.68, V₂ 18.07 cm³/mol) -

Method and standards

Modified Raoult's law with Wilson activity coefficients; bubble temperature by bisection.

Where it is used

  • Beer and rectifying column design.
  • Reading tray temperatures in distilleries.

Common mistakes

  • Using Raoult's law without activity coefficients.
  • Mixing % vol and mole fraction.

Assumptions and limits

  • Wilson energies fitted at 1 atm; 0.9–1.2 atm only.
  • Binary ethanol–water; congeners and dissolved solids ignored.

References

  • Ethanol–water VLE at about 1 atm: Wilson equation (Perry's Chemical Engineers' Handbook, 9th ed., sec. 4) with energies 399 and 933 cal/mol fitted to FireCAD ethanol–water x–y–T data at 101.325 kPa; ethanol vapour pressure Perry's 9th ed. Table 2-8; water IAPWS-IF97
  • Checked against Gmehling and Onken
  • DECHEMA Chemistry Data Series vol. I/1
  • as quoted in Perry's 9th ed. sec. 13 (simple batch distillation example)

Questions and answers

Why is the vapour so much richer than the wash?

Ethanol's activity coefficient in water is about 6 at infinite dilution, so dilute wash gives vapour several times richer.

Where is the azeotrope?

About 0.89 mole fraction (95.6 % mass, about 97 % vol) at 78.1–78.2 °C; this model gives 0.885.

How accurate is the model?

Within 0.014 in y and 0.8 °C of the fitted table, and within 0.008 of DECHEMA points quoted in Perry's.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.