Worked example
Example: Vapour 0.60 mole fraction. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Vapour strength entered as | Mole fraction |
| Vapour strength | 60.000 % |
| Pressure | 101.33 kPa |
Applying the formula below gives:
| Result | Value |
|---|---|
| Vapour mole fraction | 60.000 % |
| Dew point | 81.067 °C |
| First condensate mole fraction | 35.627 % |
| First condensate strength | 66.400 % |
| Strength of the total condensate | 84.931 % |
Open this example in the calculator and change any input.
Formula
\(y_1 = \frac{x_1\gamma_1 p_1^s(T_d)}{P}, \quad \sum y_i = 1\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\text{basis}\) | Vapour strength entered as | - |
| \(s_y\) | Vapour strength | - |
| \(P\) | Pressure | Pa |
| \(y_1\) | Vapour mole fraction | - |
| \(T_d\) | Dew point | K |
| \(x_1\) | First condensate mole fraction | - |
| \(q_x\) | First condensate strength | - |
| \(q_y\) | Strength of the total condensate | - |
| \(\gamma_1, \gamma_2\) | Activity coefficients of ethanol and water (Wilson) | - |
| \(p_1^s, p_2^s\) | Vapour pressures of ethanol and water | Pa |
Method and standards
Dew point by bisection on the liquid composition with the bubble-point solution.
Where it is used
- Dephlegmator and partial condenser design.
- Interpreting vapour-line temperatures.
Common mistakes
- Assuming condensate equals vapour strength at the dew point.
Assumptions and limits
- Wilson energies fitted at 1 atm; 0.9–1.2 atm only.
- Binary ethanol–water; congeners and dissolved solids ignored.
References
- Ethanol–water VLE at about 1 atm: Wilson equation (Perry's Chemical Engineers' Handbook, 9th ed., sec. 4) with energies 399 and 933 cal/mol fitted to FireCAD ethanol–water x–y–T data at 101.325 kPa; ethanol vapour pressure Perry's 9th ed. Table 2-8; water IAPWS-IF97
- Checked against Gmehling and Onken
- DECHEMA Chemistry Data Series vol. I/1
- as quoted in Perry's 9th ed. sec. 13 (simple batch distillation example)
Questions and answers
Why is the first condensate weaker than the vapour?
Water condenses preferentially: that is how a dephlegmator returns a weaker reflux and passes a richer vapour.
What is the total condensate strength?
If all the vapour is condensed, the liquid has the vapour's own composition.
Why must the vapour be below the azeotrope?
Above it the equilibrium reverses and this inversion has no single answer.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.