FireCADCalc

Ethanol–Water Composition from Boiling Temperature

Liquid and vapour ethanol strengths from a tray or still temperature at about 1 atm, the inverse of the bubble-point curve; used to read column temperatures.

Distillery and ethanolIAPWS-IF97 (water and steam)

Inputs

Examples: Still at 87 °CTray at 80 °C

Model fitted at 1 atm; use 0.9–1.2 atm.

Results

Near the azeotrope the temperature changes by only tenths of a degree over a wide strength range: read top-tray strength by density, not temperature.

Liquid mole fraction47.031%
Liquid strength76.439%
Liquid strength by mass69.424%
Vapour mole fraction64.633%
Condensed vapour strength87.410%

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Still at 87 °C. The inputs, in the units selected above:

InputValue
Measured boiling temperature87.000 °C
Pressure101.33 kPa

Applying the formula below gives:

ResultValue
Liquid mole fraction8.9996 %
Liquid strength24.766 %
Liquid strength by mass20.185 %
Vapour mole fraction42.249 %
Condensed vapour strength72.582 %

Open this example in the calculator and change any input.

Formula

\(T_b(x_1, P) = T_{\text{measured}}\)

Variables

Symbol Meaning SI unit
\(T\) Measured boiling temperature K
\(P\) Pressure Pa
\(x_1\) Liquid mole fraction -
\(q_x\) Liquid strength -
\(p_x\) Liquid strength by mass -
\(y_1\) Vapour mole fraction -
\(q_y\) Condensed vapour strength -

Method and standards

Inverse of the bubble-point curve by bisection.

Where it is used

  • Column temperature control.
  • Pot still cut points.

Common mistakes

  • Ignoring barometric pressure.
  • Using it near the azeotrope.

Assumptions and limits

  • Wilson energies fitted at 1 atm; 0.9–1.2 atm only.
  • Binary ethanol–water; congeners and dissolved solids ignored.
  • Near the azeotrope the bubble curve is so flat that an error of a few tenths of a degree, in the reading or in the fitted model, moves the strength a long way; no uncertainty is computed, so read strong liquids by density.

References

  • Ethanol–water VLE at about 1 atm: Wilson equation (Perry's Chemical Engineers' Handbook, 9th ed., sec. 4) with energies 399 and 933 cal/mol fitted to FireCAD ethanol–water x–y–T data at 101.325 kPa; ethanol vapour pressure Perry's 9th ed. Table 2-8; water IAPWS-IF97
  • Checked against Gmehling and Onken
  • DECHEMA Chemistry Data Series vol. I/1
  • as quoted in Perry's 9th ed. sec. 13 (simple batch distillation example)

Questions and answers

Can a pot still thermometer tell the strength?

Roughly: at 1 atm a liquid boiling at 90 °C holds about 12 % mass ethanol, at 85 °C about 29 %.

Why is it poor near the top?

Between 50 % and 90 % mole the boiling point spans only about 1.7 °C.

Does pressure matter?

Yes; a 1 kPa change shifts the boiling point by about 0.3 °C: enter the actual pressure.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.