FireCADCalc

Rectifier Minimum Reflux and Vapour Load to 95 % vol

Minimum and design reflux ratio, vapour and reflux flows of an ethanol rectifier fed with beer-column vapour, for a product strength in % vol (tangent pinch).

Distillery and ethanolIAPWS-IF97 (water and steam)

Inputs

Examples: 95 % vol from 45 % vol vapour, 100 m3/day94 % vol, liquid feed 40 %

Enter in m³/day or L/day in the unit list.
Model fitted at 1 atm; use 0.9–1.2 atm.

Results

Minimum reflux ratio0.90794
Design reflux ratio1.0895
Distillate50.431kmol/h
Vapour to the condenser105.38kmol/h
Vapour mass flow4,258.4kg/h
Reflux54.946kmol/h

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 95 % vol from 45 % vol vapour, 100 m3/day. The inputs, in the units selected above:

InputValue
Product strength95.000 %
Feed (vapour) strength, as condensate45.000 %
Feed condition (0 saturated vapour)0 -
Reflux multiple1.3000 -
Product at 20 °C4.1667 m³/h
Pressure101.33 kPa

Applying the formula below gives:

ResultValue
Minimum reflux ratio3.6928
Design reflux ratio4.8006
Distillate82.061 kmol/h
Vapour to the condenser476.01 kmol/h
Vapour mass flow19,611 kg/h
Reflux393.94 kmol/h

Open this example in the calculator and change any input.

Formula

\(\frac{R_{min}}{R_{min}+1} = \max\frac{x_D - y^*(x)}{x_D - x}, \quad V = (R + 1)D, \quad L = RD\)

Variables

Symbol Meaning SI unit
\(q_D\) Product strength -
\(q_F\) Feed (vapour) strength, as condensate -
\(q\) Feed condition (0 saturated vapour) -
\(R/R_{min}\) Reflux multiple -
\(\dot V_P\) Product at 20 °C m³/s
\(P\) Pressure Pa
\(R_{min}\) Minimum reflux ratio -
\(R\) Design reflux ratio -
\(D\) Distillate mol/s
\(V\) Vapour to the condenser mol/s
\(\dot m_V\) Vapour mass flow kg/s
\(L\) Reflux mol/s

Method and standards

Tangent-pinch minimum reflux with the fitted Wilson equilibrium; distillate moles from the product's R 22 density.

Where it is used

  • Rectifier sizing and steam budgets.

Common mistakes

  • Taking Rmin at the feed pinch.
  • Forgetting that D is molar.

Assumptions and limits

  • Wilson energies fitted at 1 atm; 0.9–1.2 atm only.
  • Binary ethanol–water; congeners and dissolved solids ignored.
  • Above about 94 % vol the product is close to the model azeotrope; small errors in the fitted equilibrium curve then change R_min a lot, and a note says so.

References

  • Ethanol–water VLE at about 1 atm: Wilson equation (Perry's Chemical Engineers' Handbook, 9th ed., sec. 4) with energies 399 and 933 cal/mol fitted to FireCAD ethanol–water x–y–T data at 101.325 kPa; ethanol vapour pressure Perry's 9th ed. Table 2-8; water IAPWS-IF97
  • Checked against Gmehling and Onken
  • DECHEMA Chemistry Data Series vol. I/1
  • as quoted in Perry's 9th ed. sec. 13 (simple batch distillation example)
  • Minimum reflux by the tangent to the equilibrium curve (Perry's 9th ed. sec. 13, McCabe–Thiele limiting cases)

Questions and answers

Why does the reflux rise steeply above 94 % vol?

The equilibrium curve approaches the diagonal near the azeotrope, so the tangent pinch needs ever more reflux.

Why feed as vapour?

Rectifiers are usually fed with vapour from the beer column (q = 0).

How do I get the condenser duty?

Multiply the vapour mass flow by the latent heat of the top vapour, or use the rectifier condenser calculator.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.