Worked example
Example: 10 t/h for 100 KLPD. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Steam to distillation (measured) | 10.000 t/h |
| Alcohol produced (absolute, measured) | 100.00 kL/d |
| Planned capacity | 150.00 kL/d |
Applying the formula below gives:
| Result | Value |
|---|---|
| Specific steam | 2.4000 kg/L |
| Steam for the planned capacity | 15.000 t/h |
Open this example in the calculator and change any input.
Formula
\(s = \frac{\dot m_s}{\dot V_a}, \quad \dot m_p = s \dot V_p\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\dot m_s\) | Steam to distillation (measured) | kg/s |
| \(\dot V_a\) | Alcohol produced (absolute, measured) | m³/s |
| \(\dot V_p\) | Planned capacity | m³/s |
| \(s\) | Specific steam | kg/m³ |
| \(\dot m_p\) | Steam for the planned capacity | kg/s |
Method and standards
Definitions.
Where it is used
- Distillery energy reporting.
- Boiler sizing for expansions.
Common mistakes
- Bulk litres used.
Assumptions and limits
- Steady operation.
- Steam is counted by mass with no pressure or enthalpy basis: compare plants and scale to a new capacity only at the same steam conditions. Scaling assumes the planned plant has the same specific steam.
References
- Definition s = ṁ_s/V̇_a (kg per litre = t/kL)
Questions and answers
Why is it in kg/L?
Steam per litre of absolute alcohol is the distillery's main energy KPI.
What lowers it?
Higher wash strength, multi-pressure heat integration and preheating the wash.
Dehydration steam?
Include the molecular sieve's steam if you compare whole plants.