FireCADCalc

Rotary Filter Air Pump, Filtrate Pump and Cake

Vacuum pump air, filtrate pump, power and cake thickness of a rotary vacuum filter from its area, drum speed and cake output (Hugot ch. 31).

Sugar mill and cogenerationPump

Inputs

Examples: 40 m2 ordinaryFlocculated cake

Hugot: 12.8 m³/(m²·h) ordinary filters; 31–32 with flocculant (Rapifloc); 15–18 at 50 cm vacuum (Louisiana).
Hugot: 480–500 L/(m²·h).
Hugot: about 0.8 kW/m² all drives and pumps.
Hugot: 60–75 kg/(m²·h).
Hugot: 3–10 min, about 5.

Results

Hugot: cake 7–13 mm thick, about 7 mm best; doubling the drum speed raises output about 1.4 times.

The cake comes out 6.4 mm thick, outside Hugot's 7–13 mm: adjust the drum speed.

State the air basis to the pump maker: air measured as free air at atmosphere and air at the filter vacuum differ by the pressure ratio (about 2 at 50 cmHg vacuum).

Vacuum pump air1,890.0m³/h
Filtrate pump28.800m³/h
Power48.000kW
Cake thickness6.4000mm

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 40 m2 ordinary. The inputs, in the units selected above:

InputValue
Filter area40.000 m²
Air drawn per m² of filter12.800 m/h
Filtrate pump capacity per m²0.49000 m/h
Power per m² of filter0.80000 kW/m²
Cake output70.000 kg/(m²·h)
Time per drum revolution5.0000 min
Cake density1,300.0 kg/m³

Applying the formula below gives:

ResultValue
Vacuum pump air512.00 m³/h
Filtrate pump19.600 m³/h
Power32.000 kW
Cake thickness4.4872 mm

Open this example in the calculator and change any input.

Formula

\(\dot V_a = q_a S, \quad \dot V_f = q_f S, \quad P = e S, \quad e_c = \frac{g\,t_r}{\rho_c}\)

Variables

Symbol Meaning SI unit
\(S\) Filter area m²
\(q_a\) Air drawn per m² of filter m/s
\(q_f\) Filtrate pump capacity per m² m/s
\(e\) Power per m² of filter W/m²
\(g\) Cake output kg/(m²·s)
\(t_r\) Time per drum revolution s
\(\rho_c\) Cake density kg/m³
\(\dot V_a\) Vacuum pump air m³/s
\(\dot V_f\) Filtrate pump m³/s
\(P\) Power W
\(e_c\) Cake thickness m

Method and standards

Hugot's specific capacities.

Where it is used

  • Sizing filter auxiliaries.
  • Checking cake formation.

Common mistakes

  • Using air at vacuum as free air.
  • Mixing wet and dry cake rates.

Assumptions and limits

  • Specific figures from practice.
  • The air volume is on the same basis as the specific figure entered; free air at atmosphere and air at the filter vacuum differ by the pressure ratio (about 2 at 50 cmHg), so state the basis when sizing the pump.
  • The cake thickness is compared with Hugot's 7–13 mm.

References

  • Hugot
  • Handbook of Cane Sugar Engineering
  • 3rd ed. (Elsevier, 1986)
  • ch. 31
  • Oliver filters
  • pp. 473–483

Questions and answers

Why so much air?

Air leaks through the cake once it forms; flocculated cakes are more open and need more.

How thick should the cake be?

About 7 mm: thicker cakes wash poorly.

Two vacuums?

Low vacuum (25–40 cmHg) to form cake, high (40–50) to wash and dry it.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.