FireCADCalc

Flocculant Dose and Solution Flow

Flocculant consumption per hour and per day and the dilute solution flow to the clarifier from the juice flow, the dose and the solution strength.

Sugar mill and cogeneration

Inputs

Examples: 3 ppm, 0.1 % solution5 ppm, 0.05 %

Per litre of juice, about ppm on juice. A dose in ppm on cane must be divided by the juice per cane (by volume) first.

Results

Dilute solutions (about 0.05–0.1 %) mix best; age the made-up solution before use.

Flocculant per hour0.75000kg/h
Flocculant per day18.000kg/d
Solution flow (density 1000 kg/m³)750.00L/h

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 3 ppm, 0.1 % solution. The inputs, in the units selected above:

InputValue
Juice flow250.00 m³/h
Flocculant dose (mg per litre of juice)3.0000 mg/L
Solution strength0.10000 %

Applying the formula below gives:

ResultValue
Flocculant per hour0.75000 kg/h
Flocculant per day18.000 kg/d
Solution flow (density 1000 kg/m³)750.00 L/h

Open this example in the calculator and change any input.

Formula

\(\dot m_f = \dot V_j c, \quad \dot V_s = \frac{\dot m_f}{w\,\rho}\)

Variables

Symbol Meaning SI unit
\(\dot V_j\) Juice flow m³/s
\(c\) Flocculant dose kg/m³
\(w\) Solution strength -
\(\dot m_f\) Flocculant per hour kg/s
\(\dot m_{f,d}\) Flocculant per day kg/s
\(\dot V_s\) Solution flow (density 1000 kg/m³) m³/s

Method and standards

Mass balance.

Where it is used

  • Clarifier chemical dosing.
  • Chemical budgets.

Common mistakes

  • Dose in ppm by mass of juice mixed with mg/L.

Assumptions and limits

  • Solution density as water.
  • The dose is per litre of juice. Doses quoted in ppm on cane must be converted with the juice-to-cane ratio before entry. No dose range is given here: find the optimum by jar tests.

References

  • Mass balance ṁ = V̇ c; solution flow = ṁ/(w ρ)

Questions and answers

Typical dose?

A few ppm on juice; find the optimum by jar tests.

Why dilute?

Strong solutions do not disperse before flocs form.

Overdosing?

Wastes chemical and can give fluffy, slow mud.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.