Worked example
Example: 42 frames 915 mm. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Crushing rate | 100.00 t/h |
| Number of frames | 42.000 - |
| Frame inside height | 0.91500 m |
| Frame inside width | 0.91500 m |
| Area needed per t cane/h (m² per t/h) | 6.0000 m² |
Applying the formula below gives:
| Result | Value |
|---|---|
| Filtering area | 70.327 m² |
| Crush the press serves | 11.721 t/h |
| Area needed | 600.00 m² |
| Frames needed | 359.00 |
Open this example in the calculator and change any input.
Formula
\(S = 2N H L_f, \quad A_S = \frac{S}{r}, \quad N_n = \left\lceil\frac{A r}{2HL_f}\right\rceil\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(A\) | Crushing rate | kg/s |
| \(N\) | Number of frames | - |
| \(H\) | Frame inside height | m |
| \(L_f\) | Frame inside width | m |
| \(r\) | Area needed per t cane/h | m² |
| \(S\) | Filtering area | m² |
| \(A_S\) | Crush the press serves | kg/s |
| \(S_n\) | Area needed | m² |
| \(N_n\) | Frames needed | - |
Method and standards
Hugot's area rule.
Where it is used
- Sizing filter presses.
- Checking press capacity.
Common mistakes
- Counting one face per frame.
- Using the plate size instead of the frame opening.
Assumptions and limits
- Area per t/h from practice; it is shown in m² per t cane/h. Hugot's table covers carbonatation and syrup filtration, not defecation mud.
References
- Hugot
- Handbook of Cane Sugar Engineering
- 3rd ed. (Elsevier, 1986)
- ch. 31
- eqn 31.1 and Table 31.1
- pp. 469–472
Questions and answers
Why two faces?
Cake builds on both cloths of each frame, so each frame gives twice its face area.
Still used?
In carbonatation and refineries; raw sugar mills use rotary vacuum or belt filters.
A 1016 mm plate?
Its frame opening is about 915 mm, giving 1.7 m² per frame.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.