FireCADCalc

Clarifier Settling Area from Settling Velocity

Settling area a clarifier needs for the juice flow and the settling velocity of the mud, and the crush it serves per m² (Hugot ch. 29, Sabi and SRI data).

Sugar mill and cogenerationTank and drum

Inputs

Examples: Tray clarifier, 1 cm/minFlocculated, 3 cm/min

Hugot: about 0.9 m³ of juice per tonne cane. Add the filtrate if it returns to the clarifier (12–20 % more).
Hugot: Sabi trays 1 cm/min; SRI rapid clarifier 10 cm/min with flocculant.

Results

Clarifier capacity depends on area, not depth (Hugot). Keep the juice velocity in each compartment below about 12 m/h to avoid turbulence.

Settling area needed111.11m²
Area per t cane/h (m² per t/h)0.55556m²
Crush the installed area serves216.00t/h

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Tray clarifier, 1 cm/min. The inputs, in the units selected above:

InputValue
Crushing rate100.00 t/h
Juice volume per tonne cane0.90000 m³/t
Settling velocity10.000 mm/min
Installed settling area150.00 m²

Applying the formula below gives:

ResultValue
Settling area needed150.00 m²
Area per t cane/h (m² per t/h)1.5000 m²
Crush the installed area serves100.00 t/h

Open this example in the calculator and change any input.

Formula

\(S_r = \frac{A\,v_j}{u}, \quad A_S = \frac{S\,u}{v_j}\)

Variables

Symbol Meaning SI unit
\(A\) Crushing rate kg/s
\(v_j\) Juice volume per tonne cane m³/kg
\(u\) Settling velocity m/s
\(S\) Installed settling area m²
\(S_r\) Settling area needed m²
\(S_r/A\) Area per t cane/h (shown as m² per t/h) m² per t/h
\(A_S\) Crush the installed area serves kg/s

Method and standards

Hindered-settling continuity.

Where it is used

  • Clarifier selection.
  • Checking capacity after a crush increase.

Common mistakes

  • Using the tray area where the deflector blocks part of it.
  • Mixing cm/min and m/h.

Assumptions and limits

  • Settling velocity from jar tests or plant data.
  • The juice volume is what reaches the clarifier: include returned filtrate, which adds 12–20 % (see the clarifier mud filtrate calculator).
  • For a multi-tray clarifier the settling area is the sum of the trays.

References

  • Hugot
  • Handbook of Cane Sugar Engineering
  • 3rd ed. (Elsevier, 1986)
  • ch. 29
  • capacity of clarifiers
  • pp. 434–445

Questions and answers

Why area and not volume?

Mud settles at a fixed speed; the clear juice must rise more slowly than that, which depends on the area the flow spreads over.

Typical values?

Conventional tray clarifiers 1–2.5 m² per t cane/h; rapid clarifiers with flocculant 0.2–0.33.

What changes the settling velocity?

Flocculant, pH, temperature, phosphate and the amount of soil in the cane.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.