FireCADCalc

Purity Drop of Mud Held in the Clarifier

Fall in purity of clarifier mud held hot over time, by Hugot's rule (eqn 29.1: t/10 up to 10 hours, t²/100 beyond), and the mud purity left.

Sugar mill and cogeneration

Inputs

Examples: 6 hoursWeekend 30 hours

Results

Rule for mud at about 95 °C and pH 6–6.5. Over weekends Hugot cools the juice to 80 °C, adds lime to pH 8.7 and a little formalin.

Purity drop (points)0.60000%
Purity after holding83.400%

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 6 hours. The inputs, in the units selected above:

InputValue
Time the mud is held6.0000 h
Purity of the mud juice when settled84.000 %

Applying the formula below gives:

ResultValue
Purity drop (points)0.60000 %
Purity after holding83.400 %

Open this example in the calculator and change any input.

Formula

\(\Delta P = \frac{t}{10}\ (0 < t \le 10\ \mathrm h), \quad \Delta P = \frac{t^2}{100}\ (t \ge 10\ \mathrm h)\)

Variables

Symbol Meaning SI unit
\(t\) Time the mud is held s
\(P_0\) Purity of the mud juice when settled -
\(\Delta P\) Purity drop (points) -
\(P\) Purity after holding -

Method and standards

Hugot's empirical rule.

Where it is used

  • Weekend shutdown planning.
  • Judging mud handling.

Common mistakes

  • Applying it to clear juice.
  • Using days instead of hours.

Assumptions and limits

  • Mud near 95 °C, pH 6–6.5; temperature and pH are not inputs. Apparent purity (brix and pol), as in routine control.
  • Beyond about a day the rule is an extrapolation; a note appears.

References

  • Hugot
  • Handbook of Cane Sugar Engineering
  • 3rd ed. (Elsevier, 1986)
  • ch. 29
  • eqn 29.1
  • p. 433

Questions and answers

Why does mud lose purity?

Sucrose inverts and decomposes in hot, slightly acid mud, and microbes act if it cools.

Why the change of formula at 10 hours?

The loss accelerates as the mud turns sour; Hugot's rule switches from linear to quadratic.

How to limit it?

Short-retention clarifiers and filtering mud promptly.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.