FireCADCalc

NPSH Available (Water)

Net positive suction head available at a pump handling water, from the suction vessel pressure, water temperature, static height and suction losses.

Thermal power plantProcess steam and utilitiesRefinery and petrochemicalChemical and fertiliserIAPWS-IF97 (water and steam)Hydraulic Institute (pumps)BoilerDeaerator and feedwater systemPump

Inputs

Examples: Deaerator at 105 °C (saturated), 8 m above the pump, 0.6 m losses, NPSHr 5 mOpen tank, water 30 °C, 2 m flooded suction, 0.5 m lossesSuction lift 3 m, water 25 °C, 0.8 m lossesHot well 60 °C at 0.25 bar(a), 1.5 m above the pump

Atmospheric for an open tank; the deaerator or vessel pressure for a closed one. Absolute; choose a gauge unit to enter gauge readings.

Results

NPSH available1.8242m
Head from pressure above vapour pressure0.52420m
Vapour pressure of water0.19946bar
Water density983.18kg/m³

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Deaerator at 105 °C (saturated), 8 m above the pump, 0.6 m losses, NPSHr 5 m. The inputs, in the units selected above:

InputValue
Pressure on the liquid surface (absolute)1.2090 bar
Water temperature105.00 °C
Liquid level above the pump centreline (negative for a lift)8.0000 m
Friction loss in the suction line0.60000 m
NPSH required by the pump (0 = skip)5.0000 m

Applying the formula below gives:

ResultValue
NPSH available7.4000 m
Margin over NPSH required2.4000 m
Head from pressure above vapour pressure0 m
Vapour pressure of water1.2090 bar
Water density954.71 kg/m³

Open this example in the calculator and change any input.

Formula

\(NPSH_a = \frac{p_s - p_v}{\rho\,g} + z - h_f\)

Variables

Symbol Meaning SI unit
\(p_s\) absolute pressure on the liquid surface Pa
\(T\) water temperature K
\(z\) liquid level above the pump centreline (negative for a lift) m
\(h_f\) friction loss in the suction line m
\(NPSH_r\) NPSH required by the pump m
\(NPSH_a\) NPSH available m
\(NPSH_a - NPSH_r\) margin (the ratio NPSHa/NPSHr is given in a note) m
\(h_p\) head from pressure above the vapour pressure m
\(p_v\) vapour pressure of water at \(T\) Pa
\(\rho\) density of saturated water at \(T\) kg/m³
\(g\) standard gravity, 9.806 65 m/s²

Method and standards

The definition of NPSH available of ANSI/HI 9.6.1, referred to the pump centreline. Vapour pressure and liquid density come from FireCAD's IAPWS-IF97 implementation on the saturation line at the water temperature.

Where it is used

  • Checking feed pump suction from the deaerator.
  • Condensate extraction and hot water transfer pumps.
  • Setting the deaerator or tank elevation.

Common mistakes

  • Using the tank pressure when the liquid is at saturation: NPSH available is then only static head less losses.
  • Ignoring the transient when a deaerator's pressure falls suddenly.
  • Comparing NPSH available with NPSH required without a margin.

Assumptions and limits

  • Water only (0.01 °C to 350 °C).
  • Lowest liquid level and highest temperature are the design case; use them.
  • Velocity head at the suction flange is included in the friction loss you enter, as is common practice.
  • Dissolved gas and transient pressure decay in a deaerator on load rejection are not covered; they need extra margin.

References

  • ANSI/HI 9.6.1 (NPSH margin)
  • IAPWS R7-97(2012) IF97 (vapour pressure, density)

Questions and answers

How is NPSH available calculated?

NPSHa = (surface pressure − vapour pressure)/(ρ·g) + static height − suction friction. For an open tank of water at 30 °C, 2 m above the pump with 0.5 m of losses, NPSHa = 9.94 + 2 − 0.5 = 11.4 m.

Why must a deaerator be mounted high?

The water in a deaerator is at its boiling point, so the pressure term is zero and the only NPSH comes from the height. With the deaerator 8 m above the pump and 0.6 m of suction losses, NPSHa is 7.4 m.

How much margin over NPSH required is needed?

ANSI/HI 9.6.1 gives margin ratios by pump type and service. The calculator shows the difference; the margin to accept is the standard's or the pump maker's.

Method and article reviewed by FireCAD engineering on 10 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.