FireCADCalc

Cathodic Protection Attenuation along a Coated Pipeline

Attenuation constant, characteristic resistance, drain current and protected length either side of a drain point on a long coated pipeline (Uhlig model).

Thermal power plantProcess steam and utilitiesRefinery and petrochemical

Inputs

Examples: Illustrative 508 mm line, 10000 ohm m2 coatingAged coating 1000 ohm m2New FBE 100000 ohm m2, 1 m line

Accepted: 20 to 3,000 mm
Accepted: 2 to 50 mm
Accepted: 10 to 100 µΩ·cm
Accepted: 0.1 to 10,000,000 Ω·m²
Accepted: 0.05 to 2 V
Accepted: 0.01 to 1 V

Results

Transmission-line model of an infinitely long pipe: ΔE(x) = ΔE₀e^(−αx), α = √(R_s/R_L), Z_c = √(R_sR_L), current each way ΔE₀/Z_c. R_s = ρ_s/[πt(D − t)], R_L = r_c/(πD). Coating resistance falls with age (from 10⁵ Ω·m² new to 10³ or less), which shortens spacing between drain points; insulating joints and the far end change the infinite-line result.

Pipe longitudinal resistance0.012099mΩ/m
Coating leakage resistance (length basis)6,265.9Ω·m
Attenuation constant4.3941e-051/m
Characteristic resistance0.27533Ω
Drain current (both directions)4.3583A
Protected length each side15.774km

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 508 mm line, 10000 ohm m2 coating. The inputs, in the units selected above:

InputValue
Pipe outside diameter508.00 mm
Wall thickness9.5000 mm
Steel resistivity18.000 µΩ·cm
Coating resistance10,000 Ω·m²
Potential shift at the drain point0.60000 V
Minimum shift needed0.30000 V

Applying the formula below gives:

ResultValue
Pipe longitudinal resistance0.012099 mΩ/m
Coating leakage resistance (length basis)6,265.9 Ω·m
Attenuation constant4.3941e-05 1/m
Characteristic resistance0.27533 Ω
Drain current (both directions)4.3583 A
Protected length each side15.774 km

Open this example in the calculator and change any input.

Formula

\(\alpha = \sqrt{\frac{R_s}{R_L}}, \quad Z_c = \sqrt{R_sR_L}, \quad L_p = \frac{1}{\alpha}\ln\frac{\Delta E_0}{\Delta E_{min}}, \quad I_0 = \frac{2\Delta E_0}{Z_c}\)

Variables

Symbol Meaning SI unit
\(D\) Pipe outside diameter m
\(t\) Wall thickness m
\(\rho_s\) Steel resistivity Ω·m
\(r_c\) Coating resistance Ω·m²
\(\Delta E_0\) Potential shift at the drain point V
\(\Delta E_{min}\) Minimum shift needed V
\(R_s\) Pipe longitudinal resistance Ω/m
\(R_L\) Coating leakage resistance (length basis) Ω·m
\(\alpha\) Attenuation constant 1/m
\(Z_c\) Characteristic resistance Ω
\(I_0\) Drain current (both directions) A
\(L_p\) Protected length each side m

Method and standards

Attenuation.

Where it is used

  • Spacing CP stations on buried pipelines.
  • Assessing coating deterioration from current demand.

Common mistakes

  • Using new-coating resistance for end-of-life design.
  • Ignoring insulating flanges and branch lines.

Assumptions and limits

  • Long uniform line; uniform coating and soil; potential shifts, not absolute potentials.

References

  • Pipeline attenuation (transmission-line) equations

Questions and answers

Why does protection fade along the pipe?

Current leaks through coating holidays as it spreads, and the pipe's own resistance drops the potential.

How does coating quality matter?

A well-coated line has high leakage resistance, so one station protects tens of kilometres; a poor coating needs many.

What do the defaults represent?

An illustrative 508 mm × 9.5 mm steel line with 10,000 Ω·m² coating, 0.6 V shift at the drain point and 0.3 V minimum.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Peabody, Control of Pipeline Corrosion, 2nd ed. (NACE, 2001), Revie and Uhlig, Corrosion and Corrosion Control, 4th ed. (Wiley, 2008)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.