FireCADCalc

Trace Moisture: ppmv to Dew or Frost Point

Dew point (over water) or frost point (over ice) of a gas from its moisture content in ppmv at line pressure, with water mass per normal volume and ppm by mass.

Process steam and utilitiesRefinery and petrochemicalChemical and fertiliserIAPWS-IF97 (water and steam)

Inputs

Examples: Illustrative 100 ppmv at 1 atmNatural gas 50 ppmv at 70 barInstrument air 2 % at 7 bar (above 0 C)

Accepted: 0.001 to 200,000 ppm
Accepted: 0.01 to 300 bar
Accepted: 2 to 100 kg/kmol

Results

p_w = y·p; the dew point is where p_w equals the saturation pressure, over ice below 0.01 °C (IAPWS sublimation equation) and over water above (IAPWS-IF97). Below 0 °C supercooled water can form a dew point a few kelvin below the frost point; analysers state which they report. No enhancement factor is applied, which matters at high pressure.

Water vapour partial pressure16,000Pa
Dew or frost point55.314°C
Water per normal cubic metre16,075mg/Nm³
Moisture by mass12,536ppm

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 100 ppmv at 1 atm. The inputs, in the units selected above:

InputValue
Moisture content100.00 ppm
Line pressure (absolute)1.0132 bar
Dry gas molar mass28.000 kg/kmol

Applying the formula below gives:

ResultValue
Water vapour partial pressure10.133 Pa
Dew or frost point-42.075 °C
Water per normal cubic metre80.374 mg/Nm³
Moisture by mass64.342 ppm

Open this example in the calculator and change any input.

Formula

\(p_w = y_wp, \quad p_{sat}(T_d) = p_w, \quad w = \frac{y_wM_w}{y_wM_w + (1 - y_w)M_g}\)

Variables

Symbol Meaning SI unit
\(y_w\) Moisture content -
\(p\) Line pressure (absolute) Pa
\(M_g\) Dry gas molar mass kg/kmol
\(p_w\) Water vapour partial pressure Pa
\(T_d\) Dew or frost point K
\(c_w\) Water per normal cubic metre kg/m³
\(w\) Moisture by mass -

Method and standards

Trace moisture.

Where it is used

  • Instrument air and nitrogen dryness.
  • Natural gas and process gas moisture specifications.

Common mistakes

  • Mixing ppmv and ppmw.
  • Converting at atmospheric pressure when the gas is at line pressure.

Assumptions and limits

  • Ideal gas mixture; no enhancement factor.

References

  • IAPWS sublimation and IF97 saturation pressure

Questions and answers

Why does pressure raise the dew point?

At the same ppmv the water's partial pressure scales with line pressure, so it condenses at a higher temperature.

Dew point or frost point below zero?

Ice is stable, so equilibrium is the frost point; some sensors report a supercooled-water dew point a few kelvin lower.

What do the defaults represent?

An illustrative 100 ppmv of moisture in nitrogen-like gas at atmospheric pressure.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Lipták, Instrument Engineers' Handbook, Vol. 1: Process Measurement and Analysis, 4th ed. (CRC, 2003)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.