FireCADCalc

Wind Turbine Tower Natural Frequency and 1P/3P Check

First bending frequency of a tubular tower with a top mass and the rotor 1P and blade-passing 3P frequency bands, to classify the tower as soft-stiff or not.

Thermal power plant

Inputs

Examples: Illustrative 90 m, 4 m x 25 mm, 150 t, 6-13 rpmStiff short tower 40 m, 2.5 m x 15 mm, 30 t, 15-28 rpmTall 140 m, 5 m x 30 mm, 250 t, 5-11 rpm

Accepted: 5 to 200 m
Accepted: 0.2 to 10 m
Accepted: 1 to 200 mm
Accepted: 1 to 400 GPa
Accepted: 1,000 to 9,000 kg/m³
Accepted: 0.01 to 1,000 t
Accepted: 0.95493 to 954.93 rpm
Accepted: 0.95493 to 954.93 rpm
Accepted: 1 to 6

Results

Cantilever with a tip mass, Rayleigh estimate f = (1/2π)√[3EI/((M + (33/140)m_t)L³)] for a uniform tube; tapered towers and foundation flexibility lower the frequency. Soft-stiff: the frequency lies between the 1P and blade-passing bands with 10 % margins.

First tower bending frequency0.25851Hz
Tower mass220.57t
1P at minimum speed0.10000Hz
1P at maximum speed0.21667Hz
Blade passing at minimum speed0.30000Hz
Blade passing at maximum speed0.65000Hz

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 90 m, 4 m x 25 mm, 150 t, 6-13 rpm. The inputs, in the units selected above:

InputValue
Tower height90.000 m
Tower outer diameter (uniform equivalent)4.0000 m
Wall thickness25.000 mm
Young's modulus210.00 GPa
Steel density7,850.0 kg/m³
Top mass (nacelle and rotor)150.00 t
Minimum rotor speed6.0000 rpm
Maximum rotor speed13.000 rpm
Number of blades3.0000 -

Applying the formula below gives:

ResultValue
First tower bending frequency0.25851 Hz
Tower mass220.57 t
1P at minimum speed0.10000 Hz
1P at maximum speed0.21667 Hz
Blade passing at minimum speed0.30000 Hz
Blade passing at maximum speed0.65000 Hz

Open this example in the calculator and change any input.

Formula

\(f_1 = \frac{1}{2\pi}\sqrt{\frac{3EI}{(M + \frac{33}{140}m_t)L^3}}, \quad f_{1P} = \frac{n}{60}, \quad f_{BP} = B\frac{n}{60}\)

Variables

Symbol Meaning SI unit
\(L\) Tower height m
\(D\) Tower outer diameter (uniform equivalent) m
\(t\) Wall thickness m
\(E\) Young's modulus Pa
\(\rho_s\) Steel density kg/m³
\(M\) Top mass (nacelle and rotor) kg
\(n_{min}\) Minimum rotor speed rad/s
\(n_{max}\) Maximum rotor speed rad/s
\(B\) Number of blades -
\(f_1\) First tower bending frequency 1/s
\(m_t\) Tower mass kg
\(1P_{min}\) 1P at minimum speed 1/s
\(1P_{max}\) 1P at maximum speed 1/s
\(BP_{min}\) Blade passing at minimum speed 1/s
\(BP_{max}\) Blade passing at maximum speed 1/s

Method and standards

Tower frequency screening.

Where it is used

  • Tower and foundation preliminary design.
  • Retrofits with heavier nacelles.

Common mistakes

  • Ignoring foundation flexibility.
  • Using the maximum rotor speed only (variable-speed rotors sweep a band).

Assumptions and limits

  • Uniform tube; fixed base; Rayleigh approximation.

References

  • Cantilever with tip mass (Rayleigh) and rotor excitation bands

Questions and answers

Why must the tower avoid 1P and 3P?

Rotor imbalance excites the tower once per revolution (1P) and each blade passing the tower excites it B times per revolution; resonance would multiply the fatigue loads.

Why are most towers soft-stiff?

A tower between the two bands needs less steel than a stiff-stiff tower and avoids the control effort of a soft-soft design.

What do the defaults represent?

An illustrative 90 m steel tube 4 m in diameter with a 25 mm wall, 150 t on top, rotor 6–13 rpm, three blades.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Manwell, McGowan and Rogers, Wind Energy Explained, 2nd ed. (Wiley, 2009), ch. 6 and 7

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.