FireCADCalc

Wind Farm Layout: Turbines per Area, Capacity Density and Energy

Number of turbines, installed capacity and capacity density of a wind farm on a given land area from turbine size and spacing in rotor diameters, with annual energy.

Thermal power plant

Inputs

Examples: Illustrative 20 km2, 4.2 MW 150 m, 7D x 4DOffshore 100 km2, 15 MW 236 m, 8D x 6DSmall 3 km2, 2 MW 90 m, 6D x 3D

Accepted: 0.01 to 30 MW
Accepted: 10 to 300 m
Accepted: 2 to 15
Accepted: 2 to 10
Accepted: 0.01 to 10,000 km²
Accepted: 5 to 70 %

Results

Rectangular grid with cells s_aD × s_cD; edge effects, terrain, setbacks and exclusions reduce the count. Large onshore farms reach about 2–5 MW per km² overall and deliver about 1–3 W per m² of land averaged over the year.

Number of turbines that fit20.000
Land per turbine0.14580km²
Installed capacity40.000MW
Capacity density (MW per km²)13.333
Annual energy98.112GWh
Energy density (average W per m² of land)3.7333W/m²

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 20 km2, 4.2 MW 150 m, 7D x 4D. The inputs, in the units selected above:

InputValue
Turbine rating4.2000 MW
Rotor diameter150.00 m
Spacing along the prevailing wind (diameters)7.0000 -
Spacing across the wind (diameters)4.0000 -
Usable site area20.000 km²
Net capacity factor (after wake and other losses)32.000 %

Applying the formula below gives:

ResultValue
Number of turbines that fit31.000
Land per turbine0.63000 km²
Installed capacity130.20 MW
Capacity density (MW per km²)6.5100
Annual energy364.98 GWh
Energy density (average W per m² of land)2.0832 W/m²

Open this example in the calculator and change any input.

Formula

\(A_t = s_aD \times s_cD, \quad N = \left\lfloor\frac{A}{A_t}\right\rfloor, \quad E = NP_t\,CF\,8760\,h\)

Variables

Symbol Meaning SI unit
\(P_t\) Turbine rating W
\(D\) Rotor diameter m
\(s_a\) Spacing along the prevailing wind (diameters) -
\(s_c\) Spacing across the wind (diameters) -
\(A\) Usable site area m²
\(CF\) Net capacity factor (after wake and other losses) -
\(N\) Number of turbines that fit -
\(A_t\) Land per turbine m²
\(P\) Installed capacity W
\(P/A\) Capacity density (MW per km²) -
\(E\) Annual energy J
\(E/(A\cdot t)\) Energy density (average W per m² of land) W/m²

Method and standards

Wind farm layout arithmetic.

Where it is used

  • Early site screening and land negotiations.
  • Comparing land use of energy sources.

Common mistakes

  • Using equal spacing in all directions at sites with a strong prevailing wind.
  • Ignoring setbacks from houses, roads and power lines.

Assumptions and limits

  • Regular grid; flat site; one turbine type.

References

  • Array spacing and capacity density

Questions and answers

Why is so much land needed?

Turbines must be several diameters apart to limit wake losses; the land between them stays in farming use, so the footprint actually occupied is only a few per cent.

What capacity density is typical?

Packing at 7D × 4D gives about 5–7 MW/km² for modern turbines; whole farms with setbacks and exclusions average about 2–5 MW/km².

What do the defaults represent?

An illustrative 20 km² site with 4.2 MW, 150 m turbines at 7D × 4D spacing and a 32 % net capacity factor.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Manwell, McGowan and Rogers, Wind Energy Explained, 2nd ed. (Wiley, 2009), ch. 9, Gilbert Masters, Renewable and Efficient Electric Power Systems (Wiley, 2004)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.