FireCADCalc

Quick Wind Capacity Factor from Mean Speed and Rotor Size

Quick estimate of a wind turbine's capacity factor and annual energy from the mean hub-height wind speed, rated power and rotor diameter for Rayleigh winds.

Thermal power plant

Inputs

Examples: Illustrative 3 MW, 120 m, 7 m/s1.5 MW, 77 m, 6.5 m/sLow-wind 4 MW, 150 m, 6 m/s

Accepted: 3 to 15 m/s
Accepted: 0.01 to 20 MW
Accepted: 5 to 300 m

Results

Empirical fit CF = 0.087V̄ − P_R/D² (V̄ in m/s, P_R in kW, D in m) to Rayleigh-wind results for real power curves; use for screening between about 0.2 and 0.5 only. For a site's own wind distribution and power curve use the Weibull energy calculator.

Capacity factor40.067%
Annual energy10,530MWh
Rating over diameter squared (kW/m²)0.20833

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 3 MW, 120 m, 7 m/s. The inputs, in the units selected above:

InputValue
Mean wind speed at hub height7.0000 m/s
Rated power3.0000 MW
Rotor diameter120.00 m

Applying the formula below gives:

ResultValue
Capacity factor40.067 %
Annual energy10,530 MWh
Rating over diameter squared (kW/m²)0.20833

Open this example in the calculator and change any input.

Formula

\(CF = 0.087\bar V - \frac{P_R}{D^2}, \quad E = CF \cdot P_R \cdot 8{,}760\,\text{h}\)

Variables

Symbol Meaning SI unit
\(\bar V\) Mean wind speed at hub height m/s
\(P_R\) Rated power W
\(D\) Rotor diameter m
\(CF\) Capacity factor -
\(E\) Annual energy J
\(P_R/D^2\) Rating over diameter squared (kW/m²) -

Method and standards

Empirical capacity factor.

Where it is used

  • Early project screening.
  • Comparing turbine models for a site.

Common mistakes

  • Using the 10 m mean speed instead of hub height.
  • Using it for very low or very high winds.

Assumptions and limits

  • Rayleigh winds; typical pitch-regulated power curves; no losses.

References

  • Empirical capacity-factor correlation for Rayleigh winds

Questions and answers

What capacity factors do wind farms achieve?

About 25–35 % onshore and 40–50 % offshore; low-specific-rating turbines on good sites exceed 40 % on land.

Why does a bigger rotor raise the capacity factor?

More swept area for the same generator reaches rated power at lower winds, so the machine spends more of the year near full output.

What do the defaults represent?

An illustrative 3 MW turbine with a 120 m rotor at a site with a 7 m/s mean wind at hub height.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Gilbert Masters, Renewable and Efficient Electric Power Systems (Wiley, 2004), ch. 6

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.