FireCADCalc

Wind Turbine Wake Deficit (Jensen / Park Model)

Wind speed and power deficit at a turbine downstream of another by the Jensen (Park) top-hat wake model, with the wake diameter and overlapping equal wakes.

Thermal power plant

Inputs

Examples: Illustrative 5D, C_T 0.8, k 0.075Offshore 7D, k 0.04, two overlapping wakesClose 3D, C_T 0.9

Accepted: 0.05 to 1
Accepted: 1 to 100,000 m
Accepted: 0.5 to 300 m
Accepted: 0.01 to 0.2
Accepted: 1 to 20

Results

Jensen (Katic) model: U_X/U₀ = 1 − (1 − √(1 − C_T))/(1 + 2kX/D)², a top-hat wake growing linearly; overlapping equal wakes add as the root sum of squares of their deficits. Full overlap assumed; part-wake and turbulence effects are not modelled.

Axial induction (1 − √(1 − C_T))/20.27639
Wake diameter at X175.00m
Wind speed ratio in the wake0.81950
Velocity deficit18.050%
Power ratio of the downstream turbine (below rated)55.036%
Spacing in rotor diameters5.0000

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 5D, C_T 0.8, k 0.075. The inputs, in the units selected above:

InputValue
Thrust coefficient of the upstream turbine0.80000 -
Downstream distance500.00 m
Rotor diameter100.00 m
Wake decay constant (0.075 onshore, 0.04–0.05 offshore)0.075000 -
Number of equal overlapping wakes1.0000 -

Applying the formula below gives:

ResultValue
Axial induction (1 − √(1 − C_T))/20.27639
Wake diameter at X175.00 m
Wind speed ratio in the wake0.81950
Velocity deficit18.050 %
Power ratio of the downstream turbine (below rated)55.036 %
Spacing in rotor diameters5.0000

Open this example in the calculator and change any input.

Formula

\(\frac{U_X}{U_0} = 1 - \frac{1 - \sqrt{1 - C_T}}{\left(1 + 2kX/D\right)^2}, \quad D_X = D + 2kX\)

Variables

Symbol Meaning SI unit
\(C_T\) Thrust coefficient of the upstream turbine -
\(X\) Downstream distance m
\(D\) Rotor diameter m
\(k\) Wake decay constant (0.075 onshore, 0.04–0.05 offshore) -
\(n\) Number of equal overlapping wakes -
\(a\) Axial induction (1 − √(1 − C_T))/2 -
\(D_X\) Wake diameter at X m
\(U_X/U_0\) Wind speed ratio in the wake -
\(1 - U_X/U_0\) Velocity deficit -
\((U_X/U_0)^3\) Power ratio of the downstream turbine (below rated) -
\(X/D\) Spacing in rotor diameters -

Method and standards

Top-hat wake model.

Where it is used

  • Wind farm layout screening.
  • Estimating array losses.

Common mistakes

  • Applying full-wake losses for all wind directions.
  • Using the onshore k offshore.

Assumptions and limits

  • Full wake overlap; neutral atmosphere; below rated wind speed for the power ratio.

References

  • Jensen (Park) wake model

Questions and answers

How far apart should turbines be?

Typically 5–9 diameters in the prevailing wind direction and 3–5 across it. In a full wake at 5D the Jensen model gives a speed deficit near 18 % and a power loss of about 45 %; averaged over all wind directions, array losses are usually 5–15 %.

Why is k smaller offshore?

Lower ambient turbulence over the sea means wakes recover more slowly.

What do the defaults represent?

An illustrative 100 m rotor with C_T 0.8, a turbine 500 m (5D) downstream, k = 0.075, single wake.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Katic, Højstrup and Jensen, A simple model for cluster efficiency, European Wind Energy Association Conference (1986), Manwell, McGowan and Rogers, Wind Energy Explained, 2nd ed. (Wiley, 2009), ch. 9

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.