FireCADCalc

Damage-Equivalent Load from Load Cycles (Miner's Rule)

Damage-equivalent load range of a fatigue load spectrum from up to five load ranges and their cycle counts, for a given S-N slope and equivalent number of cycles.

Thermal power plant

Inputs

Examples: Illustrative three bins, m 4Composite blade m 10Five bins steel m 3

Accepted: 0 to 1,000,000 kN
Accepted: 0 to 1E+12
Accepted: 0 to 1,000,000 kN
Accepted: 0 to 1E+12
Accepted: 0 to 1,000,000 kN
Accepted: 0 to 1E+12
Accepted: 0 to 1,000,000 kN
Accepted: 0 to 1E+12
Accepted: 0 to 1,000,000 kN
Accepted: 0 to 1E+12
Accepted: 1 to 20
Accepted: 1 to 1E+12

Results

DEL = (Σ nᵢSᵢᵐ / N_eq)^(1/m) from Miner's linear damage sum on an S-N curve of slope m. Load ranges come from rainflow counting of time series; the result depends strongly on m.

Damage-equivalent load range264.14kN
Total cycles1.2321e+07
Share of damage from the worst bin43.412%

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative three bins, m 4. The inputs, in the units selected above:

InputValue
Load range 1400.00 kN
Cycles at range 11,000,000 -
Load range 2800.00 kN
Cycles at range 2100,000 -
Load range 31,500.0 kN
Cycles at range 310,000 -
Load range 40 kN
Cycles at range 40 -
Load range 50 kN
Cycles at range 50 -
S-N curve slope (steel welds 3–5, composites about 10)4.0000 -
Equivalent number of cycles1.0000e+07 -

Applying the formula below gives:

ResultValue
Damage-equivalent load range329.02 kN
Total cycles1,110,000
Share of damage from the worst bin43.201 %

Open this example in the calculator and change any input.

Formula

\(DEL = \left(\frac{\sum_i n_iS_i^m}{N_{eq}}\right)^{1/m}\)

Variables

Symbol Meaning SI unit
\(S_1\) Load range 1 N
\(n_1\) Cycles at range 1 -
\(S_2\) Load range 2 N
\(n_2\) Cycles at range 2 -
\(S_3\) Load range 3 N
\(n_3\) Cycles at range 3 -
\(S_4\) Load range 4 N
\(n_4\) Cycles at range 4 -
\(S_5\) Load range 5 N
\(n_5\) Cycles at range 5 -
\(m\) S-N curve slope (steel welds 3–5, composites about 10) -
\(N_{eq}\) Equivalent number of cycles -
\(DEL\) Damage-equivalent load range N
\(\sum n_i\) Total cycles -
\(\max(n_iS_i^m)/\sum\) Share of damage from the worst bin -

Method and standards

Equivalent fatigue load.

Where it is used

  • Comparing turbine load cases and sites.
  • Fatigue screening of welded structures.

Common mistakes

  • Mixing load ranges with amplitudes.
  • Comparing DELs with different m or N_eq.

Assumptions and limits

  • Linear damage accumulation; no mean-stress correction.

References

  • Damage-equivalent load with Miner's rule

Questions and answers

Why is one bin often dominant?

Damage goes with the load range to the power m; with m = 10 for composites, rare large cycles outweigh millions of small ones.

What N_eq should I use?

A convention: often 10⁷ cycles, or 1 Hz over the design life; compare DELs only at the same N_eq and m.

What do the defaults represent?

An illustrative spectrum of 10⁶ cycles at 400 kN, 10⁵ at 800 kN and 10⁴ at 1,500 kN with m = 4 and N_eq = 10⁷.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Manwell, McGowan and Rogers, Wind Energy Explained, 2nd ed. (Wiley, 2009), ch. 6

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.