FireCADCalc

Power-to-Hydrogen-to-Power Round-Trip Efficiency

Round-trip efficiency, electricity needed per MWh returned and hydrogen per MWh when storing electricity as hydrogen and converting it back.

Thermal power plant

Inputs

Examples: Illustrative 55 + 2.5 kWh/kg, 1 %, 50 % fuel cellHydrogen turbine CCGT 60 %, cavernSmall system 60 kWh/kg, 4 kWh/kg, 45 %

Accepted: 10 to 111.11 kWh/kg
Accepted: 0 to 11.111 kWh/kg
Accepted: 0 to 50 %
Accepted: 10 to 80 %

Results

η_RT = LHV(1 − l_s)η_g/(e_el + e_c) with the hydrogen lower heating value (about 33.3 kWh/kg). Hydrogen per MWh returned counts the hydrogen burned in the reconversion step. Batteries reach 85–90 % but only for hours; hydrogen suits seasonal storage despite 30–40 %.

Round-trip efficiency28.683%
Electricity in per unit out3.4864
Hydrogen per MWh returned60.027kg
Power-to-hydrogen efficiency (LHV)57.945%

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 55 + 2.5 kWh/kg, 1 %, 50 % fuel cell. The inputs, in the units selected above:

InputValue
Electrolysis system specific energy55.000 kWh/kg
Compression and storage energy2.5000 kWh/kg
Storage and handling losses of hydrogen1.0000 %
Reconversion efficiency (LHV; fuel cell or turbine)50.000 %

Applying the formula below gives:

ResultValue
Round-trip efficiency28.683 %
Electricity in per unit out3.4864
Hydrogen per MWh returned60.027 kg
Power-to-hydrogen efficiency (LHV)57.945 %

Open this example in the calculator and change any input.

Formula

\(\eta_{RT} = \frac{LHV(1 - l_s)\eta_g}{e_{el} + e_c}\)

Variables

Symbol Meaning SI unit
\(e_{el}\) Electrolysis system specific energy J/kg
\(e_c\) Compression and storage energy J/kg
\(l_s\) Storage and handling losses of hydrogen -
\(\eta_g\) Reconversion efficiency (LHV; fuel cell or turbine) -
\(\eta_{RT}\) Round-trip efficiency -
\(E_{in}/E_{out}\) Electricity in per unit out -
\(m_{H_2}\) Hydrogen per MWh returned kg
\(\eta_{P2H}\) Power-to-hydrogen efficiency (LHV) -

Method and standards

Storage chain efficiency.

Where it is used

  • Long-duration storage studies.
  • Comparing storage technologies.

Common mistakes

  • Mixing HHV-based electrolyser and LHV-based fuel cell efficiencies.
  • Forgetting compression energy.

Assumptions and limits

  • Steady average efficiencies.

References

  • Energy chain efficiency of hydrogen storage

Questions and answers

What round-trip efficiency does hydrogen storage give?

About 25–40 %: electrolysis about 60–70 %, compression a few per cent, reconversion 40–60 %.

Why consider it then?

Hydrogen can be stored in tanks or salt caverns for months at low cost per MWh, which batteries cannot do economically.

What do the defaults represent?

An illustrative chain: 55 kWh/kg electrolysis, 2.5 kWh/kg compression, 1 % losses and a 50 % fuel cell.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Larminie and Dicks, Fuel Cell Systems Explained, 2nd ed. (Wiley, 2003), ch. 8

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.