FireCADCalc

Hydrogen Fuel Cell Reversible Voltage and Nernst Equation

Gibbs energy, reversible open-circuit voltage and efficiency limit of a hydrogen-oxygen fuel cell at any temperature, with the Nernst correction for gas pressures.

Thermal power plantChemical and fertiliser

Inputs

Examples: Illustrative PEM at 80 C, liquid water, 1.5 bar H2, 0.3 bar O2SOFC at 800 C, vapour, 0.9 bar H2, 0.21 bar O2, 0.1 bar H2OStandard 25 C, 1 bar

Accepted: 0.01 to 1,226.8 °C
Accepted: 0.001 to 100 bar
Accepted: 0.001 to 100 bar
Accepted: 1E-5 to 100 bar

Results

E⁰ = −Δg/(2F) with Δh and Δs at T from the 25 °C NIST-JANAF values and heat capacities (Shomate gases, IAPWS-IF97 liquid water). Nernst: E = E⁰ + (RT/2F) ln[p_H₂ p_O₂^½ / p_H₂O] with pressures in bar (liquid water has unit activity). Real open-circuit voltages are lower because of fuel crossover.

Enthalpy of reaction at T-284.09kJ/mol
Gibbs energy of reaction at T-228.31kJ/mol
Reversible voltage at 1 bar1.1831V
Nernst voltage at the partial pressures1.1801V
Efficiency limit Δg/Δh (higher heating value)79.876%

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative PEM at 80 C, liquid water, 1.5 bar H2, 0.3 bar O2. The inputs, in the units selected above:

InputValue
Cell temperature80.000 °C
Product waterLiquid (up to 100 °C)
Hydrogen partial pressure1.5000 bar
Oxygen partial pressure0.30000 bar
Water vapour partial pressure (vapour product only)0.50000 bar

Applying the formula below gives:

ResultValue
Enthalpy of reaction at T-284.09 kJ/mol
Gibbs energy of reaction at T-228.31 kJ/mol
Reversible voltage at 1 bar1.1831 V
Nernst voltage at the partial pressures1.1801 V
Efficiency limit Δg/Δh (higher heating value)79.876 %

Open this example in the calculator and change any input.

Formula

\(E^0 = \frac{-\Delta\bar g_f}{2F}, \quad \Delta\bar g_f = \Delta\bar h_f - T\Delta\bar s, \quad E = E^0 + \frac{RT}{2F}\ln\frac{p_{H_2}p_{O_2}^{1/2}}{p_{H_2O}}\)

Variables

Symbol Meaning SI unit
\(T\) Cell temperature K
\(\text{water}\) Product water -
\(p_{H_2}\) Hydrogen partial pressure Pa
\(p_{O_2}\) Oxygen partial pressure Pa
\(p_{H_2O}\) Water vapour partial pressure (vapour product only) Pa
\(\Delta \bar h_f\) Enthalpy of reaction at T J/mol
\(\Delta \bar g_f\) Gibbs energy of reaction at T J/mol
\(E^0\) Reversible voltage at 1 bar V
\(E\) Nernst voltage at the partial pressures V
\(\eta_{max}\) Efficiency limit Δg/Δh (higher heating value) -

Method and standards

Thermodynamics of the hydrogen-oxygen cell.

Where it is used

  • Fuel cell and electrolyser design and teaching.
  • Checking measured open-circuit voltages.

Common mistakes

  • Using the 25 °C voltage at operating temperature.
  • Putting pressures in Pa instead of bar into the logarithm.

Assumptions and limits

  • Ideal gases; pure hydrogen fuel.

References

  • Reversible cell voltage from the Gibbs energy; Nernst equation

Questions and answers

Why does the voltage fall as the cell gets hotter?

The reaction loses entropy, so Δg = Δh − TΔs becomes less negative with temperature: 1.23 V at 25 °C, about 1.18 V at 80 °C and 0.92 V at 1,000 °C.

Why can high-temperature cells still be efficient?

Their losses (activation, resistance) are much smaller, and their waste heat is hot enough to use, which outweighs the lower reversible voltage.

What do the defaults represent?

An illustrative PEM cell at 80 °C with liquid product water, hydrogen at 1.5 bar and air at 1.43 bar (oxygen 0.3 bar).

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

NIST-JANAF Thermochemical Tables, 4th ed. (Chase, 1998), Larminie and Dicks, Fuel Cell Systems Explained, 2nd ed. (Wiley, 2003), ch. 2

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.