Worked example
Example: Illustrative 30 to 450 bar, 3 stages, 100 kg/h. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Suction pressure | 3.0000 MPa |
| Discharge pressure | 45.000 MPa |
| Suction (and intercooled) temperature | 30.000 °C |
| Number of stages | 3.0000 - |
| Isentropic efficiency per stage | 75.000 % |
| Heat capacity ratio (hydrogen 1.41) | 1.4100 - |
| Hydrogen flow | 100.00 kg/h |
Applying the formula below gives:
| Result | Value |
|---|---|
| Pressure ratio per stage | 2.4662 |
| Specific work (adiabatic, intercooled) | 1.4340 kWh/kg |
| Isothermal work | 0.94049 kWh/kg |
| Isothermal efficiency | 65.587 % |
| Stage discharge temperature | 151.32 °C |
| Shaft power | 143.40 kW |
| Share of the hydrogen lower heating value | 4.3038 % |
Open this example in the calculator and change any input.
Formula
\(w = \frac{Nk}{k - 1}\frac{RT_1}{\eta_s}\left(r^{(k-1)/k} - 1\right), \quad r = \left(\frac{p_2}{p_1}\right)^{1/N}, \quad w_{iso} = RT_1\ln\frac{p_2}{p_1}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(p_1\) | Suction pressure | Pa |
| \(p_2\) | Discharge pressure | Pa |
| \(T_1\) | Suction (and intercooled) temperature | K |
| \(N\) | Number of stages | - |
| \(\eta_s\) | Isentropic efficiency per stage | - |
| \(k\) | Heat capacity ratio (hydrogen 1.41) | - |
| \(\dot m\) | Hydrogen flow | kg/s |
| \(r\) | Pressure ratio per stage | - |
| \(w\) | Specific work (adiabatic, intercooled) | J/kg |
| \(w_{iso}\) | Isothermal work | J/kg |
| \(w_{iso}/w\) | Isothermal efficiency | - |
| \(T_2\) | Stage discharge temperature | K |
| \(P\) | Shaft power | W |
| \(w/LHV\) | Share of the hydrogen lower heating value | - |
Method and standards
Compression work.
Where it is used
- Refuelling station and storage design.
- Hydrogen supply chain energy balances.
Common mistakes
- Using the molar mass of air.
- Ignoring compressibility at high pressure.
Assumptions and limits
- Ideal gas; perfect intercooling; equal stage ratios.
References
- Multistage intercooled compression of an ideal gas
Questions and answers
How much energy does compression take?
About 1.4–2 kWh/kg from 30 to 450 bar and about 2–4 kWh/kg to 900 bar for refuelling once real-gas and motor losses are included, 4–10 % of the hydrogen's lower heating value.
Why is hydrogen hard to compress?
Its very low molar mass means high gas-constant work per kilogram, and it heats up strongly, so many intercooled stages are needed.
What do the defaults represent?
An illustrative 100 kg/h compressed from 30 to 450 bar in three intercooled stages at 75 % efficiency.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Larminie and Dicks, Fuel Cell Systems Explained, 2nd ed. (Wiley, 2003), ch. 8