FireCADCalc

Hydrogen Compression Work and Power

Specific work and power to compress hydrogen in intercooled stages, against isothermal work, with stage outlet temperature and share of hydrogen energy.

Chemical and fertiliser

Inputs

Examples: Illustrative 30 to 450 bar, 3 stages, 100 kg/hRefuelling 450 to 900 bar booster, 1 stageLow-pressure electrolyser 1 to 200 bar, 4 stages

Accepted: 0.01 to 100 MPa
Accepted: 0.1 to 200 MPa
Accepted: -73.15 to 126.85 °C
Accepted: 1 to 10
Accepted: 30 to 100 %
Accepted: 1.1 to 1.67
Accepted: 0.0036 to 360,000 kg/h

Results

Ideal gas, equal pressure ratios, intercooling to T₁: w = N[k/(k − 1)]RT₁(r^((k−1)/k) − 1)/η_s. Hydrogen's compressibility (Z ≈ 1.2–1.5 at 350–700 bar) raises real work by up to about 10 %; motor and cooling losses add more.

Pressure ratio per stage2.4662
Specific work (adiabatic, intercooled)1.4340kWh/kg
Isothermal work0.94049kWh/kg
Isothermal efficiency65.587%
Stage discharge temperature151.32°C
Shaft power143.40kW
Share of the hydrogen lower heating value4.3038%

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 30 to 450 bar, 3 stages, 100 kg/h. The inputs, in the units selected above:

InputValue
Suction pressure3.0000 MPa
Discharge pressure45.000 MPa
Suction (and intercooled) temperature30.000 °C
Number of stages3.0000 -
Isentropic efficiency per stage75.000 %
Heat capacity ratio (hydrogen 1.41)1.4100 -
Hydrogen flow100.00 kg/h

Applying the formula below gives:

ResultValue
Pressure ratio per stage2.4662
Specific work (adiabatic, intercooled)1.4340 kWh/kg
Isothermal work0.94049 kWh/kg
Isothermal efficiency65.587 %
Stage discharge temperature151.32 °C
Shaft power143.40 kW
Share of the hydrogen lower heating value4.3038 %

Open this example in the calculator and change any input.

Formula

\(w = \frac{Nk}{k - 1}\frac{RT_1}{\eta_s}\left(r^{(k-1)/k} - 1\right), \quad r = \left(\frac{p_2}{p_1}\right)^{1/N}, \quad w_{iso} = RT_1\ln\frac{p_2}{p_1}\)

Variables

Symbol Meaning SI unit
\(p_1\) Suction pressure Pa
\(p_2\) Discharge pressure Pa
\(T_1\) Suction (and intercooled) temperature K
\(N\) Number of stages -
\(\eta_s\) Isentropic efficiency per stage -
\(k\) Heat capacity ratio (hydrogen 1.41) -
\(\dot m\) Hydrogen flow kg/s
\(r\) Pressure ratio per stage -
\(w\) Specific work (adiabatic, intercooled) J/kg
\(w_{iso}\) Isothermal work J/kg
\(w_{iso}/w\) Isothermal efficiency -
\(T_2\) Stage discharge temperature K
\(P\) Shaft power W
\(w/LHV\) Share of the hydrogen lower heating value -

Method and standards

Compression work.

Where it is used

  • Refuelling station and storage design.
  • Hydrogen supply chain energy balances.

Common mistakes

  • Using the molar mass of air.
  • Ignoring compressibility at high pressure.

Assumptions and limits

  • Ideal gas; perfect intercooling; equal stage ratios.

References

  • Multistage intercooled compression of an ideal gas

Questions and answers

How much energy does compression take?

About 1.4–2 kWh/kg from 30 to 450 bar and about 2–4 kWh/kg to 900 bar for refuelling once real-gas and motor losses are included, 4–10 % of the hydrogen's lower heating value.

Why is hydrogen hard to compress?

Its very low molar mass means high gas-constant work per kilogram, and it heats up strongly, so many intercooled stages are needed.

What do the defaults represent?

An illustrative 100 kg/h compressed from 30 to 450 bar in three intercooled stages at 75 % efficiency.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Larminie and Dicks, Fuel Cell Systems Explained, 2nd ed. (Wiley, 2003), ch. 8

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.