Worked example
Example: Illustrative 5 MW at 1.9 V. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Electrical power to the stacks | 5.0000 MW |
| Cell voltage | 1.9000 V |
| Faraday (current) efficiency | 98.000 % |
Applying the formula below gives:
| Result | Value |
|---|---|
| Hydrogen production | 96.994 kg/h |
| Hydrogen production (normal volume) | 1,078.4 Nm³/h |
| Specific energy (stack) | 51.550 kWh/kg |
| Specific energy per Nm³ (kWh/Nm³) | 4.6366 |
| Efficiency on the higher heating value | 76.391 % |
| Efficiency on the lower heating value | 64.634 % |
| Water consumed (stoichiometric) | 866.74 kg/h |
| Oxygen produced | 769.74 kg/h |
| Heat to remove (above the thermoneutral voltage) | 1,180.4 kW |
Open this example in the calculator and change any input.
Formula
\(\dot n_{H_2} = \frac{\eta_FP}{2FV_c}, \quad \eta_{HHV} = \eta_F\frac{1.481}{V_c}, \quad e = \frac{P}{\dot m_{H_2}}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(P\) | Electrical power to the stacks | W |
| \(V_c\) | Cell voltage | V |
| \(\eta_F\) | Faraday (current) efficiency | - |
| \(\dot m_{H_2}\) | Hydrogen production | kg/s |
| \(\dot V_{H_2}\) | Hydrogen production (normal volume) | Nm³/s |
| \(e\) | Specific energy (stack) | J/kg |
| \(e_V\) | Specific energy per Nm³ (kWh/Nm³) | - |
| \(\eta_{HHV}\) | Efficiency on the higher heating value | - |
| \(\eta_{LHV}\) | Efficiency on the lower heating value | - |
| \(\dot m_{H_2O}\) | Water consumed (stoichiometric) | kg/s |
| \(\dot m_{O_2}\) | Oxygen produced | kg/s |
| \(\dot Q\) | Heat to remove (above the thermoneutral voltage) | W |
Method and standards
Faraday's law for electrolysis.
Where it is used
- Green hydrogen project sizing.
- Comparing electrolyser offers.
Common mistakes
- Mixing stack and system specific energy.
- Quoting efficiency without saying HHV or LHV.
Assumptions and limits
- Steady operation; Faraday losses as a single efficiency.
References
- Faraday's law and thermoneutral voltage of water electrolysis
Questions and answers
How much electricity does 1 kg of hydrogen need?
At least 39.4 kWh (its higher heating value); real stacks at 1.8–2.0 V use about 48–54 kWh/kg, and whole plants 50–60 kWh/kg.
How much water is needed?
Nine kilograms per kilogram of hydrogen by stoichiometry; treatment rejects mean that 15–20 kg of raw water is typical.
What do the defaults represent?
An illustrative 5 MW electrolyser at 1.9 V per cell and 98 % Faraday efficiency.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Larminie and Dicks, Fuel Cell Systems Explained, 2nd ed. (Wiley, 2003), ch. 8