Worked example
Example: Illustrative PEM 0.90 V at 10 and 0.82 V at 100 mA/cm2. The inputs, in the units selected above:
| Input | Value |
|---|---|
| First current density | 10.000 mA/cm² |
| Cell voltage at i₁ | 0.90000 V |
| Second current density | 100.00 mA/cm² |
| Cell voltage at i₂ | 0.82000 V |
| Reversible voltage | 1.1800 V |
| Cell temperature | 80.000 °C |
Applying the formula below gives:
| Result | Value |
|---|---|
| Tafel constant (V per natural log unit) | 34.744 mV |
| Tafel slope per decade | 80.000 mV |
| Charge transfer coefficient RT/(2AF) | 0.43795 |
| Exchange current density | 0.003162 mA/cm² |
Open this example in the calculator and change any input.
Formula
\(A = \frac{V_1 - V_2}{\ln(i_2/i_1)}, \quad i_0 = i_1\exp\left(-\frac{E - V_1}{A}\right), \quad \alpha = \frac{RT}{2AF}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(i_1\) | First current density | A/m² |
| \(V_1\) | Cell voltage at i₁ | V |
| \(i_2\) | Second current density | A/m² |
| \(V_2\) | Cell voltage at i₂ | V |
| \(E\) | Reversible voltage | V |
| \(T\) | Cell temperature | K |
| \(A\) | Tafel constant (V per natural log unit) | V |
| \(b\) | Tafel slope per decade | V |
| \(\alpha\) | Charge transfer coefficient RT/(2AF) | - |
| \(i_0\) | Exchange current density | A/m² |
Method and standards
Tafel fit.
Where it is used
- Fuel cell and electrolyser testing.
- Catalyst comparison.
Common mistakes
- Using points where ohmic or mass-transport loss dominates.
- Mixing natural-log and decade slopes.
Assumptions and limits
- Activation-controlled region; one electrode dominant.
References
- Tafel equation fitted to two points
Questions and answers
Why is the exchange current so important?
It sets the activation loss: a cathode with i₀ a thousand times larger loses about 0.2–0.3 V less.
What Tafel slope is typical?
About 60–120 mV per decade for oxygen reduction on platinum, rising with current density.
What do the defaults represent?
Illustrative PEM cell points: 0.90 V at 10 mA/cm² and 0.82 V at 100 mA/cm², with E = 1.18 V at 80 °C.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Larminie and Dicks, Fuel Cell Systems Explained, 2nd ed. (Wiley, 2003), ch. 3