Worked example
Example: Illustrative natural gas 17.4 kg/kmol, 39.8 MJ/Nm3. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Natural gas molar mass | 17.400 kg/kmol |
| Natural gas gross heating value per Nm³ (MJ) | 39.800 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| Density ratio | 0.11586 |
| Volume flow ratio at the same pressure drop | 2.9378 |
| Hydrogen gross heating value per Nm³ (MJ) | 12.751 |
| Energy throughput ratio | 94.122 % |
| Compression power per unit energy delivered, ratio | 3.1213 |
Open this example in the calculator and change any input.
Formula
\(\frac{Q_{H_2}}{Q_{NG}} = \sqrt{\frac{\rho_{NG}}{\rho_{H_2}}}, \quad \frac{\dot E_{H_2}}{\dot E_{NG}} = \frac{HHV_{H_2}}{HHV_{NG}}\sqrt{\frac{\rho_{NG}}{\rho_{H_2}}}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(M_{NG}\) | Natural gas molar mass | kg/kmol |
| \(HHV_{NG}\) | Natural gas gross heating value per Nm³ (MJ) | - |
| \(\rho_{H_2}/\rho_{NG}\) | Density ratio | - |
| \(Q_{H_2}/Q_{NG}\) | Volume flow ratio at the same pressure drop | - |
| \(HHV_{H_2}\) | Hydrogen gross heating value per Nm³ (MJ) | - |
| \(\dot E_{H_2}/\dot E_{NG}\) | Energy throughput ratio | - |
| \(P_{c,H_2}/P_{c,NG}\) | Compression power per unit energy delivered, ratio | - |
Method and standards
Pipeline energy capacity.
Where it is used
- Hydrogen network planning.
- Repurposing natural gas pipelines.
Common mistakes
- Comparing volume flow instead of energy flow.
- Ignoring compressor redesign.
Assumptions and limits
- Same pressures and friction factor; ideal gases.
References
- Pipeline flow scaling with gas density
Questions and answers
Can a gas pipeline carry as much energy as hydrogen?
Nearly: hydrogen flows about three times faster for the same pressure drop, which almost makes up for its lower energy per cubic metre.
What is the catch?
Compressors must move three times the volume, using more power per unit energy, and steel embrittlement must be checked.
What do the defaults represent?
An illustrative natural gas of molar mass 17.4 kg/kmol and 39.8 MJ/Nm³.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Larminie and Dicks, Fuel Cell Systems Explained, 2nd ed. (Wiley, 2003), ch. 8